3. Fasten the copper wire on the
corresponding terminal block. The wiring
instruction is printed in front of the
terminal block (L1/L2/G).
4. Use the following torque to connect the
wire terminal to the terminal block.
Screw
Torque
M6
31 kgf.cm
26.9 lb-in
DANGER: To reduce the risk of fire,
connect only to a circuit provided with
100 amperes maximum branch circuit
overcurrent protection in accordance
with the National Electrical Code, ANSI/
NFPA 70, and the Canadian Electrical
Code, Part I, C22.2.
5. Lock the conduit on the enclosure. Refer
to the following torque.
Conduit
Torque
1 "
35 kgf.cm
30.36 lb-in
6. Remove the cable tie and connect the
jumper wire. Then, reassemble the top
cover, and fasten the M4 screw.
Screw
Torque
M4
10 kgf.cm
12 lb-in
7. Remove the insulation sheet of the
battery package.
8. Once jumper wire is connected and
battery insulation sheet removed,
reassemble the top cover using 6x M4
screws, then place the logo cover on
top, fitting into the grooves, then sliding
down into place. Please ensure logo
cover is firmly snapped into top cover
before fastening final 2 bottom M4
screws to seal the station.