12/18/2018
LPSOL-145_075_030-24-ND-I
Luci ORILEGA
145 / 75 / 30W Power supply
To ensure safe usage
The following is the safety cautions to prevent harms or damages to use and installer.
If the product is used against cautions, it may cause damages / electrifications
/
smoke
/
ignition.
Product specifications
※
unit of measure=mm
Do not use in the following environments:
- Location at high humidity.
- Location where the product is exposed to direct sunlight.
- Location where corrosive gas is generated. - Location subject to continuous vibration or shock.
- Dusty location.
- Around exhaust outlet of gas appliances.
- Location where water may splash onto the product.
- Location subject to the effects of electric fields, magnetic fields, or radio wave.
・
Cooling by free air convection
・
Over inrush current protection
・
Over temperature protection
・
Over current and voltage protection
・
Built-in active PFC function
100V
1.70typ
85
1.00typ
200V
0.83typ
88
0.98typ
242V
0.71typ
89
0.96typ
Item / Product Name
LPSOL-145-24-ND-I
24
1.05
Indoor
0
℃
~+50
℃
, 20%
〜
90%RH
(
No condensation
)
-20
℃
~+70
℃
, 10%
〜
90%RH
(
No condensation
)
Input voltage (Vac)
Input current
(Io=100%)
Output voltage (V)
Power factor
(Io=100%)
Weight (kg)
Environment
Storage temperature · humidity
Operating temperature · humidity
Structure · Performance
Conformance standard
Efficiency (%)
・
Safety standard
Product Safety Electrical appliance and materials
※
AC100~242V
・
CE (European standard)
・
EMC standard Product Safety Electrical appliance and materials
・
Corresponds to RoHS Directive
・
Corresponds to Harmonic current regulation (IEC61000-3-2)
Frequency (Hz)
50/60
6.1
Output current (A)
146
Rated power (W)
105(
※
For temperature derating)
Max usable power (W)
100V
0.90typ
83
1.00typ
200V
0.50yp
84
0.97typ
242V
0.40typ
84
0.95typ
LPSOL-075-24-ND-I
100V
0.40typ
82
1.00typ
200V
0.20typ
84
0.97typ
242V
0.16typ
84
0.96typ
LPSOL-030-24-ND-I
0.455
3.1
75
52.5(
※
For temperature derating)
0.215
1.3
30
21(
※
For temperature derating)
302
291±0.5
2
−
R 2.25
hole for screw:2
−
φ 4.5
73±
0
.5
84
60.6
4.5
12.5
73±
0
.5
■
Front view
■
Side view
AC Black:L
AC White:N
10
1
2
4
5
6
Green:
3
250
235±0.5
2
−
R 2.25
hole for screw:2
−
φ 4.5
2
3
±0
.5
35
Cable length:150
Cable length:150
Cable length:450
Cable length:450
Cable length:150
Cable length:150
2
3
±0
.5
■
Front view
4
5
6
12
3
38
4.5
■
Side view
10
1
2
DC Black:+
DC White:
-
DC Black:+
DC White:
-
DC Black:+
DC White:
-
258.6
247±0.5
2
−
R 2.25
hole for screw:2
−
φ 4.5
3
7
±0
.5
50
3
7
±0
.5
■
Front view
4
5
6
12
3
52
4.5
■
Side view
10
1
2
AC (input side)
Connect to the primary
power source
AC (input side)
Connect to the primary
power source
AC (input side)
Connect to the primary
power source
DC (output side)
Connect to LED fixture
DC (output side)
Connect to LED fixture
DC (output side)
Connect to LED fixture
LPSOL-145-24-ND-I
LPSOL-075-24-ND-I
LPSOL-030-24-ND-I
#
Item
Name Materials etc.
Upper case
Lower case
LED (green)
Output indicator
AC IN
Please be ensure to read following!
Check the connection of input and output before energization.
Use a circuit tester to make sure the output voltage indicates appropriate value before connecting a LED fixture.
Improper connection and incorrect polarity of wires can cause an accident or severe damage to the device, and it is extremely dangerous.
Installation, removal and inspection of this device requires qualified electrician.
Please be ensure to consult with electric constructor or an electronic service company.
Please make sure to turn off power before installation.
Turn on power after completing all wire constructions including LED fixture. Otherwise, electric shock might cause.
Do not connect or disconnect the input / output lead wires while power is supplied. Otherwise, electric shock might cause.
To avoid affecting heat dissipation, do not stack the device on top of each.
High ambient temperature will cause a shorter life time of the device.
Please ensure to use the device within the designed input voltage.
Loading should not exceed the rated output current value of the device.
Fire and short lifetime may cause by overcurrent.
Do not pull or damage the power cable.
Please do not install the device in places with high ambient temperature / close to flammable object / close to
heat generated object.
High voltage components are assembled in the device.
To avoid the risk of electric shock, do not touch the components with bare hand.
Be extremely careful to handle the product while or right after carrying current as the inside temperature become high.
Do not customize or replace components inside this device.
Do not use the device after dropping or having a strong impact on it.
Do not use this device as power supplies for the equipment of, such as medical, aerospace, train and nuclear industry which may
cause grave accidents done by malfunction or failure of this device.
DC OUT
Warning Label
Black:L, White:N,
Green:
VCTF 0.75sq×3C
Black:+, White:-
VCTF 1.25sq×2C
Polycarbonate, Black
Polycarbonate, Black
1
2
3
4
5
6
AC Black:L
AC White:N
Green:
AC Black:L
AC White:N
Green:
If abnormal situation found, please cut-off the primary power immediately, consult with electricians, and do not touch the device with bare hand.
Ensure the grounding according to technical standards for equipment.
Electric shock may cause by incomplete grounding.
When connecting the input/output lead wires, please make sure to connect tightly without any looseness.
Improper connection of wires may cause short circuit, ground fault, electric shock, damage of connection part, or fire.
This device is not allowed to be covered by insulation material.
Do not place any electric cables on this device.
AC input voltage should be within the input voltage range in the specification.
Lower voltage or overvoltage will shorten the lifetime of the device and may cause overheat result in fire and electric shock.