background image

FEEL GOOD THROUGH THE WARMTH FROM ELECTRICITY - www.technotherm.de

FEEL GOOD THROUGH THE WARMTH FROM ELECTRICITY - www.technotherm.de

21

|

Manual: TTB-E Duo+

GB

2.5.4.11 Off set

This op� on allows the user to calibrate the room temperature probe. Since the accuracy of the probe is 

0.1°C, there may be some discrepancy in the reading of the ambient temperature between thermost-

ats. An error margin of up to +/- 3°C can be calibrated. The default value is 0.0ºC.

2.5.4.12 Parameters

This op� on is for use of service engineers only! Do not change any parameters by yourself.

 Changing 

parameters „e.g. how hot is a 100% charge, could lead to dysfunc� on of the device and could be very 

dangerous!“

2.5.4.13 Language

With this op� on the user can change the language on the screen. You can choose one of the three available 

languages.

2.5.4.14 Reset

This op� on allows the user to return to the factory se�  ngs. All recorded informa� on, including the link to 

the Smartbox, are lost and reset to default values.

Содержание Technotherm TTB-E Duo 08

Страница 1: ...FEELGOODTHROUGHTHEWARMTHFROMELECTRICITY www technotherm de 1 Manual TTB E Duo Model TTB EDuo Manual Installa on TTB E Duo Please note and keep Changes reserved No GB 900 322 767 Edi on 02 20...

Страница 2: ...de by a professional only Appliances which are no longer used should be disconnected immediately and the connec ng cables should be cut through Dispose the appliance in accordance with local regula on...

Страница 3: ...l take the rear chimney panel 4 away and x it horizontally to the wall At least two of the moun ng holes 9 must be used see g 2 and table 1 A er making sure the rear chimney panel is pro perly xed to...

Страница 4: ...OUGHTHEWARMTHFROMELECTRICITY www technotherm de 4 Manual TTB E Duo D GB 2a 2a Model Measure A Measure B Measure C TTB E Duo 08 180 357 TTB E Duo 17 110 325 587 TTB E Duo 26 103 333 800 TTB E Duo 34 13...

Страница 5: ...2a on the inner front panel and remove them together with the insula ng panel that is xed to it The screws 2a are behind the addi onal heater and can not be reached The inner front panel needs to be s...

Страница 6: ...ring the installa on Wiring The wiring and connec on of the heater has to be done accordingly to all relevant safety standards and rules The guidelines of the local electricity u lity must also be fo...

Страница 7: ...fit resistance Supply line terminal designation tunnel resistance security guards additional heating Charging electronics Security guard charge Safety guards Air outlet charging voltage supply 24h di...

Страница 8: ...ROUGHTHEWARMTHFROMELECTRICITY www technotherm de 8 Manual TTB E Duo D GB 24h Supply Connec on op on 1 8h 14h Charge Power 24h Supply Connec on op on 2 8h 14h Charge Power Bridge with red cable Cable i...

Страница 9: ...m It is s ll necessary to ven late the room a er the rst use e g open a window If the appliance is moved and has been in use before the steps above men oned have to be followed When performing the rst...

Страница 10: ...m to sa sfy both the set temperatures of the schedule and the charging requi red to meet the needs of the schedule in the charging periods set In some cases these two aims can come into con ict If you...

Страница 11: ...temperature Navigate down in the menu Mode OK Change mode Select in the menu Con g Prog Press 5 seconds to open se ngs Go back in the menu 2 1 1 Screen icons Icon Descrip on Charging Charge percentage...

Страница 12: ...evice Type Use the and keys to select your preference and press OK to con rm To toggle between OFF and Manual Program depending on which you ve set use the OK bu on To use the Boost mode press or duri...

Страница 13: ...g mode of the storage heater To change to Manual navigate to Device Type in the se ngs menu and select Fixed Temperature See 2 2 2 2 3 Boost Mode You can use Boost Mode to override the current tempera...

Страница 14: ...struc ons below Install TTi Smart Control App Click on Install Choose Storage heater Start Search in app and press Mode OK bu on on the device for 5 seconds Heater appears in the app and the Device co...

Страница 15: ...ce se ngs press the Con g Prog bu on 5s The following screen is displayed Use the and bu ons to scroll through the menu To select an op on press the Mode OK key To con rm and go back press the Con g P...

Страница 16: ...ve between the hours of the day Press Mode OK repeatedly to adjust the temperature level Comfort 3 squares Eco 2 squares An Frost 1 squares Once the temperature levels have been selected for each hour...

Страница 17: ...n gured in Automa c Mode 2 5 4 2 Frost Protec on You can enable or disable the frost protec on func on With frost protec on the device starts to heat when the room temperature drops to 3 C and keeps i...

Страница 18: ...nt used only in o peak intervals inside the charging sche dule Not recommended PEAK Addi onal hea ng element used only in peak interval outside the charging schedule Peak only is the default se ng 2 5...

Страница 19: ...brightness if the screen is ON or OFF and the style Time ON The me that backlight is ac ve a er a bu on was pressed Default 10s Brightness ON Brightness level when backlight is enabled Default 100 Br...

Страница 20: ...re then predicts how much power to use to ensure the current temperature remains as close to the setpoint as possible It will compensate in case of a disturbance and bring the process temperature back...

Страница 21: ...default value is 0 0 C 2 5 4 12 Parameters This op on is for use of service engineers only Do not change any parameters by yourself Changing parameters e g how hot is a 100 charge could lead to dysfun...

Страница 22: ...func ons electronic room temperature control depending on the weekday and at least has one of the fol lowing characteris cs Room temperature control with detec on of an opened window With remote cont...

Страница 23: ...ed with a fan NO At nominal thermal output elmax 0 85 1 7 2 55 3 4 kW Type of hea ng power room temperature Control select one type At the minimum hea ng capacity elmin 0 85 1 7 2 55 3 4 kW Single sta...

Страница 24: ...cht LHZ GmbH Co KG Reinhard Schmidt Str 1 09217 Burgst dt Germany Phone 49 3724 66869 0 Telefax 49 3724 66869 20 info technotherm de www technotherm de Technical alterna ons errors omissions and errat...

Отзывы: