4
If you are not connecting a T1 or E1 or serial WAN
line, go on to Step 3. Otherwise, refer to the appro-
priate section.
T1 or E1 Connection
Cable needed: RJ-48C T1/E1 crossover cable (pro-
vided with SuperPipe 155 only).
1
Connect your leased line to the port labeled
WAN T1 or E1 on the SuperPipe’s back panel.
2
Connect the other end either directly to the wall
jack or through other network interface equip-
ment.
3
After you inform your service provider that
your equipment is connected and ready for ser-
vice, you are ready to start up the unit.
CAUTION: The RJ-48C cable provided
with your SuperPipe is for devices that
transmit on pins 4 and 5 and receive on
pins 1 and 2. Ask your carrier what type
of cable to use, a straight-through or
crossover.
V.35 Connection
Cable needed: DB44-to-DB25 cable (not pro-
vided).
1
Connect the DB-44 end into the S-WAN port
on the back of the SuperPipe unit.
2
Connect the DB25 end into the V.35 port of the
other device.
!
Connect T1, E1 or V.35
(Model 155)
2