VLAN Configuration
Configuring a VLAN bridge circuit
Stinger®
IP2000 Configuration Guide
3-5
Enabling bridging on the Gigabit Ethernet interface
You must enable bridging on the Gigabit Ethernet port once, to provide bridging
support for all configured VLAN IDs. For details about the other settings in the
ethernet
profile, see Chapter 2, “Gigabit Ethernet Configuration.”
The following commands enable bridging on the physical interface:
admin> read ethernet { 1 8 2 }
admin> set bridging-enabled = yes
admin> write -f
Sample VLAN bridge circuit configuration
In the sample setup shown in Figure 3-3, the remote side of the VLAN bridge circuit
connects to a CPE on a remote office LAN. The Gigabit Ethernet side connects to a
router that can access the LAN of the head office.
Figure 3-3. Sample VLAN bridge circuit
In this sample setup, the Stinger receives traffic from the CPE, packetizes it and
inserts the VLAN ID in Ethernet frame headers, and bridges the packet stream across
its Gigabit Ethernet port. It does not terminate the packets by passing them up to the
IP router software.
The external router on the Gigabit Ethernet network interprets the VLAN ID and
directs the packet stream at Layer 2 to the specified VLAN, which is the head office
network.
First, verify that bridging is enabled on the physical interface.
Then, create a
vlan-ethernet
profile. The following commands configure the Gigabit
Ethernet side of the VLAN bridge circuit with
vlan-id
50 and the
bridging-group
number 34590:
admin> new vlan-ethernet { { 1 8 2 } 50}
admin> set enabled = yes
Parameter
RADIUS attribute
Setting
bridging-group
Ascend-BIR-Bridge-
Group (7)
Number from 0 to 65535, used to group this subscriber
interface with a VLAN. Note that you cannot group
multiple LIM-side PVCs in the same system with the
same VLAN.
bridge
Ascend-Bridge (230) Enable/disable WAN packet bridging on the interface.
dial-on-broadcast
N/A
Not used by the IP2000.
IP/ATM
Network side
User side
Gigabit
Ethernet
Remote Office
Network
PC
Head Office
Network
Содержание Stinger IP2000
Страница 1: ...Stinger IP2000 Configuration Guide Part Number 7820 0976 004 For software version 9 6 0 January 2004 ...
Страница 4: ......
Страница 12: ......
Страница 14: ......
Страница 34: ......
Страница 86: ......
Страница 100: ......
Страница 120: ......
Страница 150: ......
Страница 162: ......
Страница 208: ......