Introduction to the Stinger Compact Remote ATM DSLAM
Stinger Compact Remote ATM DSLAM hardware
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
1-7
Specific components that are installed in the Stinger Compact Remote ATM DSLAM
card-cage to support these functional requirements depend upon the operational
mode for which the unit is being configured. Different components are installed to
support stand-alone or hosted operation. The Table 1-1 identifies the components
that can be installed in the Stinger CR ATM DSLAM card-cage, the functions that
they provide, and the type of operation that they support.
Table 1-1. Functional listing of card-cage components
Component
Function(s) provided
Operational
mode
Standard
control module
Operational control of the unit, including local
management interface for configuration and
management
Stand-alone
IP2000 control
module
Operational control of the unit, including local
management interface for configuration and
management
Upstream connection from a gigabit Ethernet
interface
Stand-alone
COP
Operational control of the unit (no local
management interface)
Upstream connection from a 155Mbps optical
interface
Hosted
T1-IMA LIM
Upstream connections from T1 interfaces
Stand-alone
ADSL
LIM/RLIM
DSL connections to individual end-users
Note
A LIM in a hosted unit is identified as an
RLIM in the TAOS interface of the host.
Hosted or
stand-alone
ADSL2+ LIM
DSL connections to individual end-users
Stand-alone
SHDSL LIM
DSL connections to individual end-users
Stand-alone
LPM with
splitters
Physical connections for analog facilities from
the central office, and facilities providing
analog service with DSL to end-users.
Physical connections for T1 interfaces from an
adjacent T1-IMA LIM.
Hosted or
stand-alone
Stand-alone
Cooling unit
Operational support (cooling: self-contained
internal fan and power to an external fan)
Hosted or
stand-alone
±190Vdc Power
supply
Operational support (power conversion)
Hosted or
stand-alone
-48Vdc Power
supply
Operational support for native -48Vdc
Hosted or
stand-alone