255-700-585
3-23
PacketStar
®
PSAX 3-Port DS3/E3 ATM Protection Module User Guide
, Issue 1
Release 10.0.0
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Ports
3
If
E3
is not the value displayed in the Operating Mode field, select the
value
E3
to place the module into E3 mode.
4
Select the
Apply Operating Mode Change
command.
Field Descriptions
The read-only fields in this window are described in Table 3-6.
Table 3-6. Protection 3-Port E3 ATM Configuration
Field Name
Field Value
Description
Slot: Default:
N/A
Range: Variable
Format: Numeric
Specifies the PSAX 4500 chassis slot that the
selected module occupies.
Port
(display only)
Default:
N/A
Range: 1–3
Format: Numeric
Specifies the physical port on the module.
Interface Type
(display only)
Default:
Unconfig-
ured
Range: N/A
Format: Predefined
Specifies the type of end-to-end connection pro-
tocol that governs the transmission parameters of
this configured port and channel interface.
Unconfigured
Indicates that this interface is not configured
AtmUni3-0
Indicates that this interface is configured for the
ATM UNI 3.0 interface.
AtmUni3-1
Indicates that this interface is configured for the
ATM UNI 3.1 interface.
AtmUni4-0
Indicates that this interface is configured for the
ATM UNI 4.0 interface.
AtmPnni1_0
Indicates that this interface is configured for the
ATM PNNI 1.0 interface.
IispUser
Indicates that this interface is configured for the
ATM IISP user interface.
IispNetwork
Indicates that this interface is configured for the
ATM IISP network interface.