ACO active
....................................................................................................................................................................................................................................
ACO active
Audible office alarms (normally active) are being suppressed.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Not Alarmed
AID (type)
Blank
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
INHAUDB
Effect on
Service
Standing Condition (SC)
Alarm Entity
Type
COM
Description
ACO active
Likely Cause
User entered an
opr-aco
command through the
WaveStar
®
CIT command:
Fault
→
Alarm Cutoff
or pressed the ACO test (
ACO/TST
) push-button
on SYSCTL circuit pack faceplate.
Visible
indication
Lighted
ACO/TST
LED on SYSCTL faceplate.
Action
No action necessary. Condition clears
automatically when a new alarm is detected or all
alarms clear.
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 8
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005