Procedure 5-3: Clear
″
AGNE communication failure
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
AGNE communication failure
alarm indicated by a lighted Major (
CR/MJ
) LED on the SYSCTL
faceplate and reported as major in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure, refer to
and
in this chapter.
Procedure
Complete the following steps to identify and clear an
AGNE
communication failure
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, select
Administration
→
View NE Administration
, to check the provisioning of the AGNE for
that NE’s alarm group.
Result:
The View NE Administration window opens.
............................................................................................................................................................
2
Is the local NE the alarm gateway network element (AGNE)? Alarm
Gateway: ENABLED.
If...
Then...
Yes
The local NE is the AGNE for the
alarm group. Record the alarm group
and proceed to
No
Continue with
............................................................................................................................................................
3
Can you determine the AGNE for the alarm group? Alarm Gateway
Address List: TID of AGNE
If...
Then...
Yes
Record that TID and the alarm group
of the local NE and log into that NE
and select
Administration
→
View NE
Administration
.
Continue with
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 4
Lucent Technologies
365-372-333 R2.1