inconsistent DCC values
....................................................................................................................................................................................................................................
inconsistent DCC values
The fibers are misconnected or LAPD Role parameter is provisioned
the same value at both ends of the optical line.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Major (MJ)
AID (type)
Section Data Communications Channel (DCC)
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
OSILINKERR
Effect on
Service
NSA
Alarm Entity
Type
COM
Description
inconsistent DCC values
Likely Cause
Fibers are misconnected or DCC LAPD Role
parameter was incorrectly provisioned.
Visible
indication
Lighted
CR/MJ
LED on SYSCTL faceplate.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 7 0
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005