MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-391
QCC Optional Features
3
Call Type Queue Priority Level
3
Use this procedure to assign a priority value (1 to 7) that determines the order in
which calls programmed to ring into the QCC queue are sent to QCC system
operator positions. A value of 1 is the highest priority. The QCC queue priority
level is assigned for the following types of calls:
■
Dial 0 calls (internal calls to the system operator)
■
DID calls to invalid destinations (unassigned extension numbers)
■
Calls to the Listed Directory Number (extension for the QCC queue)
■
Calls programmed to return to the QCC queue (returning from extending,
camped-on, held calls, and operator parked calls)
■
Group Coverage calls
■
Calls signed in (Follow) or forwarded to the system operator
■
Calls to a system operator extension number
This procedure does not include programming the QCC queue priority level for
individual lines or trunks to ring into the queue.
See ‘‘QCC Queue Priority Level’’
Summary: Call Type Queue Priority Level
3
Programmable by
System Manager
Mode
Hybrid/PBX
Idle Condition
Not required
Planning Form
Form 6a, Optional Operator Features
Factory Setting
4
Valid Entries
1 to 7
Inspect
No
Copy Option
No
Console Procedure
Operator
→
Queued
Call
→
Call
Types
→
Select
call type
→
Priority
→
Dial group coverage number
(1
–
30)
→
Enter
→
Drop
→
Dial priority level (1
–
7)
→
Enter
→
Exit
→
Exit
→
Exit
→
Exit
PC Procedure
→
→
→
Select call type
→
→
Type
Group Coverage number (1
–
30)
→
→
7%
+
%
I
→
Type priority level (1
–
7)
→
→
→
→
→