
.................................................................................................................................................................................................
6
Click the
Edit...
button of the
SCN/SNN IP Address
field and enter the IP address.
NOTE:
The SCN/SNN IP address can be provisioned to any value in the range 0.0.0.0
to 223.255.255.255, with the following exceptions:
•
Addresses in the range 224.0.0.0 to 239.255.255.255 are multicast group addresses.
Addresses in the range 240.0.0.0 to 255.255.255.255 are reserved for special cases.
•
The IP address shall not be 0.0.0.0.
•
The first (most significant) number in the IP address shall not have the value 127.
The IP addresses starting with 127 (127.x.x.x) are loopback addresses.
.................................................................................................................................................................................................
7
Click
OK
and then
Close
.
.................................................................................................................................................................................................
8
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Provision...
Result:
The
Provision Parameters for Protection Groups or Equipment
window
appears. The
Equip
selection tab appears on the left side of the window.
.................................................................................................................................................................................................
9
Select “
LambdaUnite
®
MSS” and click
Provision
.
Result:
The selection window for the system parameters appears on the right-hand
side of the window. This window consists of two tabs,
Settings
and
Date and
Time
.
.................................................................................................................................................................................................
10
Select the
Settings
tab and set the
Cross-Connect Application
to
ONNS
.
.................................................................................................................................................................................................
11
Click the
Apply
pushbutton and confirm the resulting system message by clicking
Yes
.
.................................................................................................................................................................................................
12
In the
WaveStar
®
CIT
System View
, select
Fault
→
Enter/Exit Maintenance
Condition...
→
Exit Maintenance Condition...
.
Result:
The
LambdaUnite
®
MSS NE will now perform a system reset. As a
consequence, the management association between the
WaveStar
®
CIT and the NE
will be lost. After about ten minutes a new NE login can be performed.
.................................................................................................................................................................................................
13
Repeat
to
for all other NEs within the network.
E
N D
O F
S
T E P S
........................................................................................................................................................................................................................
Network establishment and testing
Setting the IP address and ONNS system parameters of
the SCN nodes
.................................................................................................................................................................................................................................
10-82
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005