Hardware Installation
2-24
Issue 2 December 1996
Task 8: Install the Control-Link Cable
This task is required only if the DEFINITY AUDIX system is to be run in the CL
integration mode.
The control-link cable can be connected to the switch in one of the following six
ways:
■
Directly to the processor interface (PI) board
■
Via an IDI to the processor interface (PI) board (TN765)
■
Via an MPDM to the digital-line interface board (TN754)
■
Via an IDI to the packet gateway board (TN577) of a G3r only
■
Via DSUs to the packet gateway board (TN577) of a G3r only
■
Via MPDMs to the packet gateway board (TN577) of a G3r only
Use Worksheet A-4 to determine which of the six cable-connection
configurations to install. Then follow the steps in one of the following four
subsections.
In the steps in the following subsections, the equipment described is
cross-referenced to the circled numbers in the figures.
Connect to the PI without an IDI
!
WARNING:
Electric shock and/or fire may result from a cabinet-to-cabinet connection of
the H600-406 control-link cable. Direct connection of the H600-406
control-link cable is to be used within a single cabinet only.
Refer to Figure 2-11, Connecting the Control Link Cable to the PI without an IDI,
when performing this task.