Task 8: Install the Control-Link Cable
Issue 2 December 1996
2-25
Figure 2-11.
Connecting the Control Link Cable to the PI without an IDI
1. Attach the one end of the synchronous null modem cable to the RS-232C
connector labeled PORT B on the MFB Y-cable (labeled 1). (The MFB
Y-cable is connected to the fourth slot of the five DEFINITY AUDIX system
slots.)
2. Attach the other end of the synchronous null modem cable to an EIA
connector of the Processor Interface (PI) board on the switch (labeled 2).
3. Proceed to Task 9: Install the Printer (Optional).
Connect to the PI with an IDI
Refer to Figure 2-12, Connecting the Control Link Cable to the PI with an IDI,
when performing this task.
H600-353, Grp 2
ALB
CABLE
1
H600-406, Grp 1 or 2
SYNCHRONOUS
NULL MODEM
CABLE
PORT A
PORT B
DEFINITY AUDIX
MULTI-
FUNCTION
BOARD
SWITCH
DEFINITY AUDIX
ALARM
BOARD
MFB
Y
CABLE
2
PI / EIA
PI / TN765
Most Switches*
Except G3r
H600-352
Grp 1
and switches using the EIA connector on the PI board for another adjunct (such as CMS).
* Other excluded switches are: duplicated G3i, switches on DC power, System 75 R1V3 without a PI/EIA port,