9-22 Issue 9 October 1998
363-206-204
Release 13 (TARP) Installation Tests
Final Operations
Procedure
1. Verify that all test signals and loopbacks from the DDM-2000 OC-3 have
been removed.
2. Press the UPD pushbutton on the SYSCTL.
3. Verify that the system is configured for normal operation and that no alarms
are present
4. If alarms are present, refer to the "Troubleshooting" section of this manual.
5. Connect the office alarm cables if they have been disconnected.
Table 9-1. Cross-Connections for DSX-1 Testing
Function Group A
Function Group B
Function Group C
m-1-1-1,a-1-1
m-1-1-2,a-1-2
m-1-1-3,a-1-3
m-1-1-4,a-1-4
m-2-1-1,b-1-1
m-2-1-2,b-1-2
m-2-1-3,b-1-3
m-2-1-4,b-1-4
m-3-1-1,c-1-1
m-3-1-2,c-1-2
m-3-1-3,c-1-3
m-3-1-4,c-1-4
m-1-2-1,a-2-1
m-1-2-2,a-2-2
m-1-2-3,a-2-3
m-1-2-4,a-2-4
m-2-2-1,b-2-1
m-2-2-2,b-2-2
m-2-2-3,b-2-3
m-2-2-4,b-2-4
m-3-2-1,c-2-1
m-3-2-2,c-2-2
m-3-2-3,c-2-3
m-3-2-4,c-2-4
m-1-3-1,a-3-1
m-1-3-2,a-3-2
m-1-3-3,a-3-3
m-1-3-4,a-3-4
m-2-3-1,b-3-1
m-2-3-2,b-3-2
m-2-3-3,b-3-3
m-2-3-4,b-3-4
m-3-3-1,c-3-1
m-3-3-2,c-3-2
m-3-3-3,c-3-3
m-3-3-4,c-3-4
m-1-4-1,a-4-1
m-1-4-2,a-4-2
m-1-4-3,a-4-3
m-1-4-4,a-4-4
m-2-4-1,b-4-1
m-2-4-2,b-4-2
m-2-4-3,b-4-3
m-2-4-4,b-4-4
m-3-4-1,c-4-1
m-3-4-2,c-4-2
m-3-4-3,c-4-3
m-3-4-4,c-4-4
m-1-5-1,a-5-1
m-1-5-2,a-5-2
m-1-5-3,a-5-3
m-1-5-4,a-5-4
m-2-5-1,b-5-1
m-2-5-2,b-5-2
m-2-5-3,b-5-3
m-2-5-4,b-5-4
m-3-5-1,c-5-1
m-3-5-2,c-5-2
m-3-5-3,c-5-3
m-3-5-4,c-5-4
m-1-6-1,a-6-1
m-1-6-2,a-6-2
m-1-6-3,a-6-3
m-1-6-4,a-6-4
m-2-6-1,b-6-1
m-2-6-2,b-6-2
m-2-6-3,b-6-3
m-2-6-4,b-6-4
m-3-6-1,c-6-1
m-3-6-2,c-6-2
m-3-6-3,c-6-3
m-3-6-4,c-6-4
m-1-7-1,a-7-1
m-1-7-2,a-7-2
m-1-7-3,a-7-3
m-1-7-4,a-7-4
m-2-7-1,b-7-1
m-2-7-2,b-7-2
m-2-7-3,b-7-3
m-2-7-4,b-7-4
m-3-7-1,c-7-1
m-3-7-2,c-7-2
m-3-7-3,c-7-3
m-3-7-4,c-7-4
Содержание DDM-2000 OC-3
Страница 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Страница 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Страница 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Страница 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Страница 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Страница 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Страница 143: ...363 206 204 Equipment and Rear Access Cable Installation Issue 9 October 1998 2 69 Figure 2 19 RJ 45 Plug and Face ...
Страница 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Страница 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Страница 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Страница 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Страница 362: ...8 30 Issue 9 October 1998 363 206 204 Releases 9 and 11 Installation Tests Figure 8 2 DDM 2000 User Panel ...
Страница 395: ...363 206 204 Release 13 TARP Installation Tests Issue 9 October 1998 9 29 Figure 9 2 DDM 2000 User Panel ...
Страница 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Страница 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Страница 492: ...IN 14 Issue 9 October 1998 ...