363-206-204
Releases 9 and 11 Installation Tests
Issue 9 October 1998 8-7
NOTE
:
The default shelf is the one physically connected to the CIT. To determine
what shelves can be entered enter a
?
.
3. After entering a valid shelf number and pressing the return (or Enter) key
the user is presented with:
login<
NOTE
:
If the Return (or Enter) key is pressed without entering a shelf number the
shelf to which you are physically attached will be accessed.
NOTE
:
There is a special login and password already programmed into the system
for use during the execution of these tests. The login is
LUC01
and the
password is
DDM-2000
. For circuit packs and shelves manufactured up to,
but not including,1 October 1996, the login is
ATT01
. This older login may
have been upgraded to
LUC01
if newer software has been installed. Both
login and password must be UPPERCASE
NOTE
:
The login and password must be entered in uppercase as shown.
After a successful login, the DDM-2000 OC-3 will display the system
header followed by the alarm and status report:
Lucent DDM-2000 OC-3 Release a.b.c (October 1, 1996, and later). This
will be in a banner and additional text describing the use restrictions and
proprietary status will follow.
AT&T DDM-2000 OC-3 Release a.b.c (before October 1, 1996). This will be
in a banner and additional text describing the use restrictions and propri-
etary status will follow.
TID date time
/* Active Alarms and Status Report */
NOTE
:
Release a.b.c is the software release. TID is the Target Identifier of the
shelf. Date and time are the current system time of the shelf.
Once logged on, the user can only issue commands to the on-line shelf. To
communicate with another shelf in the bay, the user will first have to termi-
nate the session with the current shelf. The session is terminated with the
log;
(LOGOUT) command.
4. Issue the command
init-sys:all;
(INITIALIZE-SYSTEM). This com-
mand will configure the DDM-2000 OC-3 with its default parameters.
Содержание DDM-2000 OC-3
Страница 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Страница 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Страница 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Страница 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Страница 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Страница 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Страница 143: ...363 206 204 Equipment and Rear Access Cable Installation Issue 9 October 1998 2 69 Figure 2 19 RJ 45 Plug and Face ...
Страница 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Страница 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Страница 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Страница 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Страница 362: ...8 30 Issue 9 October 1998 363 206 204 Releases 9 and 11 Installation Tests Figure 8 2 DDM 2000 User Panel ...
Страница 395: ...363 206 204 Release 13 TARP Installation Tests Issue 9 October 1998 9 29 Figure 9 2 DDM 2000 User Panel ...
Страница 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Страница 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Страница 492: ...IN 14 Issue 9 October 1998 ...