Beta Draft Confidential
Configuring PNNI Routing
Configuring PNNI Routing
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
21-43
Configuring PNNI Node Parameters
To begin using the PNNI routing protocol in your Lucent network, you need to
configure the PNNI node parameters for each switch that supports PNNI in the
network.
Adding PNNI Node Parameters
To configure PNNI node information for up to eight node instances for the switch you
select:
1. Expand the instance node for the switch to which you want to add a PNNI node.
2. Right-click on the PNNI Nodes class node and select Add from the pop-up menu.
The Add PNNI Node dialog box appears (
Figure 21-13.
Add PNNI Node Dialog Box
3. Complete the fields in the Add PNNI Node dialog box, as described in
Содержание CBX 3500