Configuring SVC Parameters
Configuring Node Prefixes
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
17-37
Custom AESA Node Prefix Format
Complete the following fields for the Custom AESA format (
Figure 17-18.
Add SVC Node Prefix: Custom AESA Format
1. In the AFI field, enter the custom AFI you want to use.
2. Enter the customized address format, starting with the HO-DSP, followed by the
ESI and SEL values (in that order).
This address can be up to 19 octets (38 hex digits) long, with 12 octets used for the
HO-DSP, 6 octets used for the ESI, and 1 octet used for the SEL. You do not have
to enter the entire address; the HO-DSP, ESI, and SEL entries are optional.
However, you must enter the AFI digits. For information about these items, see
.
3. As you type the address, the value in the Bit Length field changes to indicate the
number of address bits that are checked during call screening and call routing.
(The value increases by eight with each pair of address digits you type.) Click
another radio button to decrease the number of address bits checked, thereby
enabling the node to perform call screening and call routing down to the bit level.
You can decrease the value by 1-7 bits.
Note – To register the AESA address in the attached DTE devices’ ILMI prefix table,
enter exactly the first 13 octets (26 digits) of the AESA address. Address registration
occurs only on ILMI-enabled UNI ports with prefixes that have the Address
Registration field set to enabled (see