1/19/05
7-59
Interoperability in Lucent Switch Networks
Switches with VNN OSPF optimized flooding enabled can interoperate in Lucent
switch networks with either or both of the following:
•
Lucent CBX 500 and GX 550 switches running Release 08.00.03.00 or greater on
which VNN OSPF optimized flooding is disabled (the default setting)
•
Lucent switches running releases prior to 08.00.03.00 that do not support the
VNN OSPF optimized flooding feature
Switches on which VNN OSPF optimized flooding is disabled or unsupported will use
standard OSPF flooding mechanisms to flood the LSAs on all multiple parallel trunk
interfaces. The switch receiving the LSA will still acknowledge the LSA on the
interface on which it was received, regardless of whether VNN OSPF optimized
flooding is supported on that switch.
Enabling and Disabling VNN OSPF Optimized Flooding
To enable or disable VNN OSPF optimized flooding on a CBX 500 or GX 550 switch:
1. Right-click on the Switch instance node for the switch you want to modify, and
select Modify from the pop-up menu.
The Modify Switch dialog box appears (
Figure 7-24.
Modify Switch Dialog Box