Beta Draft Confidential
7-10
1/19/05
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Trunks
About APS
CBX 3500 Notes:
•
Intercard APS
–
Uni-directional APS is not supported on the Universal IOP; only
bi-directional APS is supported.
–
Intercard APS is supported only between two Universal IOPs. It is not
supported between a Universal IOP and an IOM1 in the CBX 3500.
•
CID Server
CID Server functionality for the Universal IOP is not supported in this release.
Once a port is configured for APS, CID space is partitioned into static allocation
for each port on the Universal IOP.
•
Universal IOP
•
The CBX 3500 ATM Universal IOP supports both inter-card and intra-card
APS, while the POS Universal IOP supports only intra-card APS.
See the Switch Module Configuration Guide
for CBX 3500, CBX 500, GX 550, and
B-STDX 9000
for a listing of the minimum software and hardware versions that support
the various APS options.
The following sections summarize these options.
1-Port OC-48/
STM-16 Phy
UNI
a
,
Direct
trunk
b
PVC
GR-253,
G.783/
G.841
Annex B
Bi-directional
Non-revertive
Inter-card
a
APS support provided by Resilient UNI.
b
APS support provided by APS trunk backup.
Table 7-2.
Slow APS Support
Switch/
Modules
Logical
Port
Circuit
Type
Base
Standard
Direction
Reversion
Inter or
Intra
card
Содержание CBX 3500