LUCCI ARENA II Скачать руководство пользователя страница 3

Installation Instructions 

 

3

  | 

P a g e  

 

        v 1 . 0   p u b l i s h e d   o n   0 7 .   2 0 1 7

 

6. 

Connect the mains supply wire and fitting power cord to an IP44 rating terminal block (Not included). Ensure that 
the wires are secure and no bare wires are exposed. Additional silicon may need to be added to maintain the 
IP44 rating of the fitting. Fig. 7 

Mains Supply Wire   

 

 

 

Wiring Label

 

Earth – Yellow/Green  

 

 

 

Yellow/Green 

Neutral – Blue or Black   

 

 

N (Neutral) 

Live – Brown or Red  

 

 

 

L (Live)   

7. 

Adjust the LED body and PIR sensor to the desired position. 

8. 

Switch the power to circuit back ON only after all electrical work has been fully completed and the fitting is fully 
assembled and is ready to use for the first time. 

 

 
SENSOR SETTINGS: 
DURATION  TIME:

  The  length  of  time  the  light  will  remain  switched  on  after 

activation can be adjusted from 12secs ±5 to 6mins ±2. Rotating the time knob 
from (+) to (-) will reduce the duration time.   
NOTE: Once the  light has been triggered by the PIR  sensor, any subsequent 
detection will start the timed period again from the beginning, the light will remain 
on until there is no movement detected. 

 

ADJUSTING THE SENSITIVITY: 

The sensitivity means the maximum distance 

which PIR Sensor can be triggered by body movement. Turning the SENS knob 

+ to -

 will decrease the sensitivity. 

 

LUX LEVEL:

 The lux control module has a built-in sensing device (photocell) that detects daylight and darkness. The 

(

) position means that the fitting will work at both day and night. The (

) position will only work at night. 

NOTE: If you want to test the detection area of the PIR sensor, please wait for the ambient light level is below 5 lux. 

SENSOR TESTING: 

1. 

Put the LUX control knob to the light (

) position and the TIME control knob to minimum (-). 

2. 

Direct the sensor toward the desired area to be scanned by twisting the sensor left and right. 

3. 

Have someone walk across the centre of the area to be scanned and slowly adjust the angle of the sensor  until 
the fitting can sense the moving person and causes the light to switch on. 

4. 

Adjust the TIME control knob to the desired length of time for the fitting to remain on. 

5. 

Adjust the LUX control knob to achieve the ideal ambient light for the fitting to switch “on”. 
For the fitting to switch ‘on’ when the ambient light is darker, switch the LUX control knob from (

) to (

). 

For the fitting to switch ‘on’ when the ambient light is brighter, switch the LUX control knob from (

) to (

). 

Отзывы: