background image

Installation Instructions 

 

2 | 

P a g e                                                             V e r s i o n   3 . 0 ( 2 0 1 9 / 0 8 )        

Installation Directions 

 

 

 

 

 

 

WARNING – HIGH VOLTAGE 

-

 

For your safety: Power to the circuit must be disconnected or switched off. 

-

 

Household power can cause SERIOUS INJURY or DEATH. 

-

 

Wiring must meet all local and national electrical wiring codes. 

 

 

MAKING THE ELECTRICAL CONNECTIONS (see Fig.1) 

1. 

Disconnect electrical power from the working circuit. 

2.    Connect 240V ~ mains

 L 

to 

L

 of the dimmer.   

3.    Connect              of the dimmer to the LOAD. 

4.    Connect the 

LOAD N

 to the 240V~ mains 

N

5.    Optional - adjust the 

variable resistor

 to optimize the dimming range for the connected LED LOAD. 

 

(Note: More LED type LOADs can be connected in series, up to the maximum allowable per LOAD type outline in 

the “installation requirements” section of this manual.) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: An isolation wall switch must be included in the wiring installation. The switch allows disconnecting of 

the  dimmer  and  loads  from  the  mains  240VAC  power  during  maintenance  and  cleaning  of  the  LED  lighting 

equipment. 

 

 

FIGURE 1. Wiring Diagram 

Wiring Diagram 

Wiring Diagram 

Variable 
Resistor   

NOTE: The Variable Resistor on the LEDlux LED Dimmer allows correcting 

and maximizing dimming range when using the LEDlux Dimmable LED 

product range from Beacon Lighting. Turn clockwise to reduce the lowest 

dimming level, turn anti-clockwise to increase the lowest dimming level.   