Installation Instructions
2 |
P a g e V e r s i o n 3 . 0 ( 2 0 1 9 / 0 8 )
Installation Directions
WARNING – HIGH VOLTAGE
-
For your safety: Power to the circuit must be disconnected or switched off.
-
Household power can cause SERIOUS INJURY or DEATH.
-
Wiring must meet all local and national electrical wiring codes.
MAKING THE ELECTRICAL CONNECTIONS (see Fig.1)
1.
Disconnect electrical power from the working circuit.
2. Connect 240V ~ mains
L
to
L
of the dimmer.
3. Connect of the dimmer to the LOAD.
4. Connect the
LOAD N
to the 240V~ mains
N
.
5. Optional - adjust the
variable resistor
to optimize the dimming range for the connected LED LOAD.
(Note: More LED type LOADs can be connected in series, up to the maximum allowable per LOAD type outline in
the “installation requirements” section of this manual.)
Note: An isolation wall switch must be included in the wiring installation. The switch allows disconnecting of
the dimmer and loads from the mains 240VAC power during maintenance and cleaning of the LED lighting
equipment.
FIGURE 1. Wiring Diagram
Wiring Diagram
Wiring Diagram
Variable
Resistor
NOTE: The Variable Resistor on the LEDlux LED Dimmer allows correcting
and maximizing dimming range when using the LEDlux Dimmable LED
product range from Beacon Lighting. Turn clockwise to reduce the lowest
dimming level, turn anti-clockwise to increase the lowest dimming level.