Test and 

Ti

me Setting

Test and Time Setting

ALP01 Pump

Operation Period Adjustment

To change the preset operation period:

1. Use the magnetic cap vertically close to the Setup EM induction

point to active the setting mode till the preset/default operation

period LED turns on, then move the cap away.

2. Use the magnetic cap close to the induction point again for at

least 3 seconds to adjust the length of the operation period.

3. The light jumps to the next value after removing the cap*.

4. Repeat the step 2 and 3 to choose the required length of the

operation period.

5. Move the cap away, let the LED of the required value be lighting

for 5 seconds and flashing once to save the setting.

6. Put the magnetic cap back to the top of the lubricator.

Adjustment of the operation period length finishes.

* The jumping sequence is 1 - 3 - 6 - 12 - 24 - 1

The original setting of the operation period length is 6 (6 months)

Test Cycle

Use the magnetic cap close to the Test induction point for at least 3

seconds, then move the cap away. The lubricator starts

immediately a manual greasing cycle (fixed running time as around

20 seconds* and the total greasing volume around 0.6 cm

3

).

During the running time, use the cap to close the test induction

point again can immediately stop the cycle.

During the test cycle running time, the LED for corresponding

setting of the operation period will continue to flash until the running

cycle ends.

Recommended:

After the lubricator is long inactive or the battery

is replaced, start a test greasing cycle to ensure that the lubricator

works in goods position and confirm the current setting of the

operation period.

* The length of the manual running time equals a normal programmed

running time, is around 20 seconds. It can be longed depends on the

working situation and type of lubricant (max. 60 seconds).

Dia. 8.2

Test Greasing 
Cycle

Dia. 8.1

Adjustment of 

Operation Period Length

About Being Idle

Caution

: A function of stopping the lubricator is NOT available in

our standard version. Please take off the battery during a long term

maintenance of the equipment.

Produc

t Manual 

-ALP

01 S

ingle 

Point

 Lubric

ator

Содержание ALP01

Страница 1: ...PRODUCT MANUAL ALP01 Single Point Lubricator Copyright of Lubmann GmbH Version 2020 01 GB ...

Страница 2: ...x Product Manual ALP01 Single Point Lubricator Index ALP01 Pump Overview 3 4 Grease Filling 5 Grease Refilling Period 6 Test and Time Setting 7 8 System Debugging 9 Installation Dimension 10 Accessories 11 12 ...

Страница 3: ...lubricator directly like in Dia 3 1 or by a progressive dividers system like in Dia 3 2 It can reduce the friction resistance reduce contact wear and decrease the friction surface temperature Meanwhile it plays a supporting role of anti rust shock absorption and sealing ALP01 Pump Dia 3 1 Single point Lubricator ALP01 connected with Greasing Point Dia 3 2 Single point Lubricator ALP01 connected wi...

Страница 4: ...p Max number of outlet 1 Max operating pressure 40 bar Max outlets by connecting a divider 8 Permissible operating temperature 20 C to 60 C Noise lvl under idling operation 65 dB Standard outlet connector thread R 3 8 Greasing Volume per stroke 0 24 cm3 Greasing volume per operation cycle 0 72 cm3 Reservoir size 120 250 500 ml Protection type IP65 as per ISO Max volume of refilled grease Lifetime ...

Страница 5: ...ght be built in the reservoir To get rid of the air bubble the level of the grease needs to be around 1 2 mm higher than the ventilation hole to drain the air bubble out of the reservoir Dia 5 2 Start a test greasing cycle to check the lubricant comes out from the lubricator outlet Make sure there is no air bubble mixed in the lubricant Otherwise continue the test greasing cycles Too much air bubb...

Страница 6: ... for 120 mL Reservoir Grease Consumption for 250 mL Reservoir Grease Consumption for 500 mL Reservoir Preset Operation Period Grease Refilling Period Per Month Per Week Per Month Per Week Per Month Per Week 24 Months 20 Months 5 0 cm3 1 1 cm3 10 4 cm3 2 3 cm3 20 8 cm3 4 6 cm3 12 Months 10 Months 10 0 cm3 2 3 cm3 20 8 cm3 4 6 cm3 41 7 cm3 9 3 cm3 6 Months 5 Months 20 0 cm3 4 6 cm3 41 7 cm3 9 3 cm3 ...

Страница 7: ...error code such as Low Battery or overloading of the lubricator EM Induction Area Users can contact the EM induction area by using the magnetic cap to adjust the operation period or to implement a manual greasing cycle 3 Test Test induction point for starting a manual greasing cycle 4 Setup Setup induction point for operation period length adjustment First Time Running When the single point lubric...

Страница 8: ...tion point for at least 3 seconds then move the cap away The lubricator starts immediately a manual greasing cycle fixed running time as around 20 seconds and the total greasing volume around 0 6 cm3 During the running time use the cap to close the test induction point again can immediately stop the cycle During the test cycle running time the LED for corresponding setting of the operation period ...

Страница 9: ... the running time of the lubricator the controller will detect the working current of the motor in real time If the detected motor current is more than 750mA for 4 consecutive seconds the lubricator will send an error code on the LED indicator area like in Dia 9 2 The lubricator is overloading internal pressure higher than 40 bar The error code remains until the failure is removed Dia 9 1 No motor...

Страница 10: ...oint Lubricator B A Level MIn Level MAx D3 D1 D2 D4 D3 A B G D1 ALP01 Reservoir Size H1 mm H2 mm H3 mm D1 mm D2 mm D3 mm D4 mm G 120 ml 192 147 107 84 80 84 78 5 R 3 8 250 ml 222 177 500 ml 282 237 R 3 8 is standard connecting thread for other connection thread requirement please contact us ...

Страница 11: ...ry Set with fixing parts 2010120530 Item Specification Part No Single Point Lubricator ALP01 120ml with battery 2010110240 ALP01 120ml without battery 2010110210 ALP01 250ml with battery 2010110230 ALP01 250ml without battery 2010110200 ALP01 500ml with battery 2010110220 ALP01 500ml without battery 2010110190 Dia 11 1 Single Point Lubricator with without Battery Dia 11 2 Single Point Lubricator B...

Страница 12: ...ass Coupling G3 8 F M12x1 25 M 3050105370 Brass Coupling G3 8 F NPT1 8 M 3050105380 Dia 12 2 Couplings for Greasing Point Connection Item Type Specification Part No Couplings for Bracket A Elbow High Pressure Quick Coupling xxx bar G3 8 D8 2010120420 B Elbow Double Cone Drive Coupling G3 8 D8 2010120400 C Straight High Pressure Quick Coupling xxx bar G3 8 D8 2010120410 D Straight Double Cone Drive...

Отзывы: