2. Precharge warning 

Only for FMDE and FMDX units.

Units are delivered from the manufacturer 

with an overpressure. Check pressure on the 

Schrader valve. With unpressurised unit:  

immediate report to manufacturer and note on 

bill of delivery. 

3. Electrical warning

Electrically powered component. Switch off 

power supply before any maintenance or instal-

lation activity.

4. Close carefully

When opening/closing the driptray, pay atten-

tion in order to avoid interference between 

impellers and fan collars. 

5. Eurovent

All FMDE models are 

EUROVENT

 certified.

Certified data:

• Capacities (ENV 327)

• Air quantities

• Motor power consumption

• External surfaces

 - 

A.Rottigni

31188585

LU-VE S.p.A. 

21040 Uboldo (VA) ITALIA - Via Caduti Della Liberazione, 53 

Tel: 00390296716.1 - Fax: 003996780560

www.luve.it - e-mail: [email protected]

CUSTOMER

ISSUE

CHANGE REASON

CHANGE DATE

DRAWN BY

STATUS

MATERIAL CODE

PROJECTION

GENERAL TOL.

DESCRIPTION

WEIGHT

 KG

U.M.

MATERIAL

DRAW DATE

CREATED BY

APPROVAL DATE

APPROVED BY

IT14 - ±1°

03/07/2020 A.Rottigni

00

-

A.Rottigni

03/07/2020

Controlled

This drawing is the property of LU-VE Group, any reproduction and/or distribution without LU-VE Group approval is unlawful.

STICKER_FMD_FAN SHROUD

0

Thick.

1,2 mm

03/07/2020

PVC, Non plastificato

mm

30

210

DIMENSIONI: 210 x 30 mm

SCRITTE:       colori (--)

FONDO:         trasparente (--)

MATERIALE:  PVC autodesivo

                       (tipo mactact)

                                    

     cod.8129_90 micron

 

DIMENSIONS:     210 x 30 mm

WRITTEN:           colors (--)

BACKGROUND: transparent (--)

MATERIAL:         PVC self-adhesive

                            (type mactact)

                                    

          code 8129_90 micron

 

Содержание Alfa LU-VE Optigo FMD

Страница 1: ...ORIGINAL INSTRUCTIONS 31114051EN 03 Optigo FMD Instruction manual Product description Product labels Unpacking lifting Installation Maintenance Spare parts...

Страница 2: ......

Страница 3: ...n 2 1 General information and application 5 2 2 Standard configuration 5 2 3 Options 5 2 4 Code description 6 3 Product labels 7 4 Unpacking and lifting 9 5 Installation 5 1 Mounting dimensions 11 5 2...

Страница 4: ...following standards PED 2014 68 EU Safety of Machinery EN 60204 1 Directive 2014 30 EC and subsequent modifications Electromagnetic compatibility Low Voltage Reference Directive 2014 35 EC However it...

Страница 5: ...ed from internally grooved Cu tubes and aluminium fins Optigo FMD coolers are available with 1 to 4 fans All models are standard fitted with EC fan motors Integrated thermo contacts Durable aluminium...

Страница 6: ...r cooler 2 Refrigerant system E HFC X CO2 W brine 3 Casing type 1 to 4 4 Number of fans 1 to 4 5 Coil type 1 2 6 Fin spacing 3 3 0 4 4 5 7 7 0 mm 7 Defrost system N air defrost E electric defrost 8 Pa...

Страница 7: ...Product labels Manufacturer MODEL COIL VENTILATION DEFROSTING CODE S N Fluid R404A VOLUME 1 83 dm3 Ts 40 C 55 C Max Pres 2 4 MPa Nr Motors 2 Tens 230 V 50 Hz 85 W 0 6 A Nr 1 230 V 900W MADE IN POLAND...

Страница 8: ...on in order to avoid interference between impellers and fan collars 5 Eurovent All FMDE models are EUROVENT certified Certified data Capacities ENV 327 Air quantities Motor power consumption External...

Страница 9: ...ing and lifting 50 mm max 3 max 2 In order to avoid damage to the air cooler or fall ing of the unit ensure that the lifting forks cover all beams from the lower support pallet Casing type 1 and 2 mod...

Страница 10: ...transparent protection film from painted metallic parts if present Lift the unit to mounting position and secure following instructions given in chapter 5 Installation After having secured the cooler...

Страница 11: ...ructions as given in the air cooler product manual AHE00042 5 1 Mounting dimensions Detailed drawings showing all required mounting and refrigerant connection dimensions are available available for do...

Страница 12: ...eiling by securely tightening nuts and washers 5 3 Refrigerant connections Do not adapt headers position to the suction line 8 mm Ensure the supply circuit is closed no pressure before connecting the...

Страница 13: ...7 x Ts1 Te Keep the superheat as low as possible to obtain maximum unit cooler performance The thermostatic valve fitted must be correctly sized for the installation conditions and adjusted for correc...

Страница 14: ...ck them with their respective gland Connect terminals by following the wiring diagrams on the cover When all connections are made refit the terminal block cover For systems using electrical hot gas de...

Страница 15: ...serves the right to change specifications without prior notification FMD FMD EB1 OPTIONAL FMD standard EB1 OPTIONAL 200 W FMD FMD EB1 5 8 Electric defrost connections FMD FMD EB1 F M D FMD E B 1 Casin...

Страница 16: ...n impellers and fan collars 6 1 Driptray heater elements replacement Always disconnect power supply before handling heater elements Disconnect drain line Remove fixing bolts and open the driptray F an...

Страница 17: ...fications without prior notification 7 Spare parts Spare parts Optigo FMD 1 Fan guard 2 Fan motor 3 Drain tray kit 4 Electrical heater 5 Side cover hairpins side 6 Side cover connections side 7 Drain...

Страница 18: ......

Страница 19: ......

Страница 20: ...alfa luvegroup com...

Отзывы: