LU-VE Alfa LU-VE Optigo FMD Скачать руководство пользователя страница 1

ORIGINAL INSTRUCTIONS

31114051EN-03

Optigo FMD

Instruction manual

•  Product description

•  Product labels

•  Unpacking & lifting

•  Installation

•  Maintenance

•  Spare parts

Содержание Alfa LU-VE Optigo FMD

Страница 1: ...ORIGINAL INSTRUCTIONS 31114051EN 03 Optigo FMD Instruction manual Product description Product labels Unpacking lifting Installation Maintenance Spare parts...

Страница 2: ......

Страница 3: ...n 2 1 General information and application 5 2 2 Standard configuration 5 2 3 Options 5 2 4 Code description 6 3 Product labels 7 4 Unpacking and lifting 9 5 Installation 5 1 Mounting dimensions 11 5 2...

Страница 4: ...following standards PED 2014 68 EU Safety of Machinery EN 60204 1 Directive 2014 30 EC and subsequent modifications Electromagnetic compatibility Low Voltage Reference Directive 2014 35 EC However it...

Страница 5: ...ed from internally grooved Cu tubes and aluminium fins Optigo FMD coolers are available with 1 to 4 fans All models are standard fitted with EC fan motors Integrated thermo contacts Durable aluminium...

Страница 6: ...r cooler 2 Refrigerant system E HFC X CO2 W brine 3 Casing type 1 to 4 4 Number of fans 1 to 4 5 Coil type 1 2 6 Fin spacing 3 3 0 4 4 5 7 7 0 mm 7 Defrost system N air defrost E electric defrost 8 Pa...

Страница 7: ...Product labels Manufacturer MODEL COIL VENTILATION DEFROSTING CODE S N Fluid R404A VOLUME 1 83 dm3 Ts 40 C 55 C Max Pres 2 4 MPa Nr Motors 2 Tens 230 V 50 Hz 85 W 0 6 A Nr 1 230 V 900W MADE IN POLAND...

Страница 8: ...on in order to avoid interference between impellers and fan collars 5 Eurovent All FMDE models are EUROVENT certified Certified data Capacities ENV 327 Air quantities Motor power consumption External...

Страница 9: ...ing and lifting 50 mm max 3 max 2 In order to avoid damage to the air cooler or fall ing of the unit ensure that the lifting forks cover all beams from the lower support pallet Casing type 1 and 2 mod...

Страница 10: ...transparent protection film from painted metallic parts if present Lift the unit to mounting position and secure following instructions given in chapter 5 Installation After having secured the cooler...

Страница 11: ...ructions as given in the air cooler product manual AHE00042 5 1 Mounting dimensions Detailed drawings showing all required mounting and refrigerant connection dimensions are available available for do...

Страница 12: ...eiling by securely tightening nuts and washers 5 3 Refrigerant connections Do not adapt headers position to the suction line 8 mm Ensure the supply circuit is closed no pressure before connecting the...

Страница 13: ...7 x Ts1 Te Keep the superheat as low as possible to obtain maximum unit cooler performance The thermostatic valve fitted must be correctly sized for the installation conditions and adjusted for correc...

Страница 14: ...ck them with their respective gland Connect terminals by following the wiring diagrams on the cover When all connections are made refit the terminal block cover For systems using electrical hot gas de...

Страница 15: ...serves the right to change specifications without prior notification FMD FMD EB1 OPTIONAL FMD standard EB1 OPTIONAL 200 W FMD FMD EB1 5 8 Electric defrost connections FMD FMD EB1 F M D FMD E B 1 Casin...

Страница 16: ...n impellers and fan collars 6 1 Driptray heater elements replacement Always disconnect power supply before handling heater elements Disconnect drain line Remove fixing bolts and open the driptray F an...

Страница 17: ...fications without prior notification 7 Spare parts Spare parts Optigo FMD 1 Fan guard 2 Fan motor 3 Drain tray kit 4 Electrical heater 5 Side cover hairpins side 6 Side cover connections side 7 Drain...

Страница 18: ......

Страница 19: ......

Страница 20: ...alfa luvegroup com...

Отзывы: