background image

Installation Manual of IR High-Definition Network Speed Dome 

20 

then insert M8 expansion screws (not supplied) into the holes.

 

(2)

 

Pull the cables through the cable hole of the mounting base.

 

(3)

 

Attach the  mounting  base  to the  ceiling by  aligning  the  screw holes  of the  mounting  base 
with the expansion screws on the ceiling.

 

(4)

 

Secure the mounting base by using nuts and washers to tighten the four expansion screws.

 

 

Figure 2-20

 

Install the Mounting Base 

 

Note

Make sure that the cables are long enough. For outdoor applications, please apply 

waterproof measures between the ceiling surface and mounting base and around the cable hole. 
The pendant mounting application is not recommended for places where the speed dome is easily 
caught in the rain. 
 
2.

 

Install the pendant pole. 

Steps: 

(1)

 

Pull out the cables through the pendant pole and screw the pendant pole into the mounting 
base. 

(2)

 

Secure the pendant pole and mounting base with the set screws. 

Note:

 

For outdoor applications, please apply the water-proof thread compound to the threads.   

 

 

Figure 2-21

 

Ceiling Mount 

3.

 

Install  the  speed  dome  to  the  mount.  Please  refer  to  Section 

1.1  Installation  and  Cabling

  for 

installation details. 

Содержание LTPTZIP762X20IR

Страница 1: ...IR High definition Network Speed Dome Installation Manual...

Страница 2: ...readily improve or update the products or procedures described in the manual DISCLAIMER STATEMENT Underwriters Laboratories Inc UL has not tested the performance or reliability of the security or sig...

Страница 3: ...any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply th...

Страница 4: ...ard Please make sure that the power has been disconnected before you wire install or dismantle the speed dome When the product is installed on wall or ceiling the device shall be firmly fixed If smoke...

Страница 5: ...ce coating of the dome cover Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover do not use alkaline detergents Do not stare at infrared LED closely to avoid hurti...

Страница 6: ...ications 11 2 1 1 Components 11 2 1 2 Wall Mounting 12 3 2 Corner Mounting Applications 13 3 2 1 Components 13 3 2 2 Corner Mounting 14 3 3 Pole Mounting Applications 15 3 3 1 Components 15 3 3 2 Pole...

Страница 7: ...d all the assembly parts are included Note Do not drag the waterproof cables as shown in Figure 1 1 otherwise the waterproof performance is affected Figure 1 1 Do not Drag the Cables 1 1 Installation...

Страница 8: ...the Wall Mount Notes For cement wall you need to use the expansion screw to fix the mount The mounting hole of the expansion pipe on the wall should align with the mounting hole on the mount For woode...

Страница 9: ...he cables of the speed dome through the wall mount 3 Connect the corresponding cables For the detailed information please refer to section 1 1 2 Connecting the Cables Figure 1 6 Install the Speed Dome...

Страница 10: ...les The cable interfaces of speed dome are shown in the following figures Please refer to the following figure for connecting the cables VI EO D RED AC24V YELLOW GREEN BLACK AC24V ORANGE RS48 YELLOW R...

Страница 11: ...r DC power supply left diagram the input voltage must be no more than 30VDC 1A For AC power supply the external relay must be used right diagram to prevent damages to the speed dome and avoid risk of...

Страница 12: ...should align with the mounting hole on the mount For wooden wall you can just use the self tapping screw to fix the mount The wall must be thick enough to install the expansion screws Please make sure...

Страница 13: ...upplied into the mounting holes 2 Attach the gasket not supplied then wall mount to the wall by aligning the 4 screw holes of the mount with expansion screws on the wall 3 Secure the wall mount with 4...

Страница 14: ...is applicable to the indoor outdoor 90 solid corner construction 3 2 1 Components Wall Mount Figure 2 5 Wall Mount Corner Adapter A corner adapter has to be used together with a wall mount for corner...

Страница 15: ...rner with the nuts and washers to tighten the four expansion screws Figure 2 8 Install the Corner Adapter Note Make sure that the cables have enough length For outdoor applications please apply the se...

Страница 16: ...work Speed Dome 15 details Figure 2 10 Finish the Installation 3 3 Pole Mounting Applications 3 3 1 Components Wall Mount Figure 2 11 Wall Mount Pole Adapter A pole adapter has to be used together wit...

Страница 17: ...ng with pole adapter and wall mount There are following dimensions selectable 59 82mm 84 108mm 103 127mm 130 152mm 155 178mm 180 203mm and 194 216mm Dimensions can be customized according to your dema...

Страница 18: ...e adapter 1 Loosen the three pole mounting hoops with a screwdriver 2 Insert them through the rectangle holes of the pole adapter Figure 2 15 Assemble the Hoops and the Pole adapter 2 Install the pole...

Страница 19: ...the water proof measures 3 Install the wall mount 1 Attach the gasket then wall mount to the pole adapter 2 Secure the wall mount to the pole adapter with 4 hex screws and the spring washers Figure 2...

Страница 20: ...18 Finish the Installation 3 4 Pendant Mounting Applications 3 4 1 Components Pendant Mount Figure 2 19 Pendant Mount 3 4 2 Pendant Mounting Steps 1 Install the mounting base Steps 1 Drill four 8 hol...

Страница 21: ...long enough For outdoor applications please apply waterproof measures between the ceiling surface and mounting base and around the cable hole The pendant mounting application is not recommended for pl...

Страница 22: ...Installation Manual of IR High Definition Network Speed Dome 21 Figure 2 22 Install the Dome...

Страница 23: ...en In strong thunderstorm area or high induction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be added T...

Страница 24: ...ely insulating to the earth e g cement pole or cement wall then only the control center requires proper grounded locally Refer to the following figure Power Power Power supply board Power supply board...

Страница 25: ...ages If the dome is installed in strong thunderstorm area it must be grounded locally to release lightening or suchlike high energy to protect dome against damages Refer to the following figure Power...

Страница 26: ...center must be grounded locally as well Refer to the following figure Power Power Power supply board Power supply board Video cable Control line Metal pole surface Display Operating Center Keyboard D...

Страница 27: ...e adapter applied between the mount and the dome Do not install indoor speed dome to the outdoor environment L shape Pole Mount Make sure that the L shape pole mount is designed with a certain inclina...

Страница 28: ...Installation Manual of IR High Definition Network Speed Dome 27 Figure A 6 Long arm Wall Mount...

Страница 29: ...cratch or image blur Please refer to the following method to clean the bubble Handling dust Use oil free soft brush or blowing dust ball to clean the dust Handling oil Steps 1 Wipe off the water drop...

Страница 30: ...terference situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased Connection Methods RS485 industry bus standard require daisy chain co...

Страница 31: ...S485 communication Problem Possible Reasons To Solve the Problem The speed dome does the self test action but cannot be controlled remotely 1 The address or baudrate of the speed dome does not match w...

Страница 32: ...easons To Solve the Problem dome can be controlled but not smoothly tightly 2 RS485 or RS485 wire is broken 2 Change a RS485 wire 3 The speed dome is too far away from the remote control device 3 Add...

Страница 33: ...is required as the minimum wire gauge 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56...

Страница 34: ...e Gauge Standards Bare Wire Gauge mm American Wire Gauge AWG British Wire Gauge SWG Cross sectional Area of Bare Wire mm2 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250...