Network Video Recorder User Manual
42
devices are configured for the UPnP™ settings under the same router,
the value of the port No. for each device should be unique.
4. Set the virtual server of your router, including internal source port, external source port, etc.
The virtual server parameters shall be corresponding with your device port.
6.2.4 NTP
Your device can connect to a network time protocol (NTP) server to ensure that the system time is
accurate.
Steps
1. Go to
Configuration
→
Network
→
General
→
NTP
.
2. Turn on
Enable
.
3. Enter the parameters.
Interval
Time interval between two time synchronization with NTP server.
NTP Server
IP address of the NTP server.
4. Click
Apply
.
6.2.5 Ports (More Settings)
Set different port types to enable relevant functions as your desire.
Go to
Configuration
→
Network
→
General
→
More Settings
.
Alarm Host IP/Port
The device will send the alarm event or exception message to the alarm host when an alarm is
triggered. The remote alarm host must have the client management system (CMS) software
installed.
Alarm Host IP
refers to the IP address of the remote PC on which the CMS software (e.g., NVMS
V3) is installed, and the Alarm Host Port (7200 by default) must be the same as the alarm
monitoring port configured in the software.
Server Port
For remote client software access. Ranges from 2000 to 65535. The default value is 8000.
HTTP Port
For remote web browser access. The default value is 80.
Multicast IP
Multicast can be configured to enable live view for cameras that exceed the maximum number
allowed through network. A multicast IP address covers Class-D IP ranging from 224.0.0.0 to
239.255.255.255 and it is recommended to use the IP address ranging from 239.252.0.0 to
Содержание LTN07256-R16