manualshive.com logo in svg
background image

 

Video  Intercom  Main  Unit 

Quick Start Guide 

Содержание LTH-M201-C

Страница 1: ...Video Intercom Main Unit Quick Start Guide...

Страница 2: ...ESS FOR A PARTICULAR PURPOSE REGARDING THIS MANUAL COMPANY DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF THE MANUAL OR THE CORRECTNESS ACCURACY OR RELIABILITY OF INFORMAT...

Страница 3: ...nce by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit dif...

Страница 4: ...icipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or m...

Страница 5: ...e over heat or fire hazard Please make sure that the power has been disconnected before you wire install or dismantle the device When the product is installed on wall or ceiling the device shall be fi...

Страница 6: ...sor at the same time Please use a soft and dry cloth when clean inside and outside surfaces of the device cover do not use alkaline detergents Please keep all wrappers after unpack them for future use...

Страница 7: ...e Mounting 7 3 2 2 One Module Flush Mounting 11 3 3 Two Module Installation 15 3 3 1 Two Module Surface Mounting 15 3 3 2 Two Module Flush Mounting 20 3 4 Three Module Installation 25 3 4 1 Three Modu...

Страница 8: ...in Camera 4 Loudspeaker 5 Call Button 6 Nametag 7 TAMPER 8 Network Interface 9 Module connecting Interface output 10 Terminals Nametag area supports insert customized name card The suggested card siz...

Страница 9: ...r Lock Relay Output NC A2 NO1 Door Lock Relay Output NO A3 COM Common Interface A4 NC2 Door Lock Relay Output NC A5 NO2 Door Lock Relay Output NO A6 GND Grounding A7 12V DC Power Supply Output A8 GND...

Страница 10: ...E 802 3af at Compliant Devices 2 2 Wiring Description 2 2 1 Door Lock Wiring Figure 2 2 Door Lock Wiring Terminal NC1 COM is set as default for accessing magnetic lock electric bolt terminal NO2 COM i...

Страница 11: ...gnetic Wiring AIN1 and AIN2 are defaulted to connect door magnetic Door magnetic connected to AIN1 detects status of the lock that connected to NC1 NO1 Door magnetic connected to AIN2 detects the stat...

Страница 12: ...it Quick Start Guide 5 AIN3 and AIN4 are set as default for connecting exit button Exit button connected to AIN3 opens the lock connected to NC1 NO1 Exit button connected to AIN4 controls the lock tha...

Страница 13: ...ienter Buy corresponding accessory package for installation The accessory package model and its suitable installation method as below Package Model Mounting Method Note LTH M201 1S One Module Surface...

Страница 14: ...20 is you set it as on Valid sub module address range is 1 to 8 The No should be unique for sub modules that connected to the same main unit The sub module address and corresponding switch status as b...

Страница 15: ...only The actual size can be slightly different from the theoretical dimension Steps 1 Paste the installation Sticker 1 onto the wall Make sure the sticker is placed leveled via measuring with the gra...

Страница 16: ...Intercom Main Unit Quick Start Guide 9 Figure 3 3 Chisel Screw Hole 3 Remove the sticker and insert the expansion sleeves into the screw holes 4 Fix the mounting frame onto the wall with 4 expansion...

Страница 17: ...Figure 3 4 Fix the Mounting Frame The mounting frame should be placed exactly as below for this step The tamper plate should be at the low right 5 Connect the cables to the corresponding interfaces o...

Страница 18: ...Intercom Main Unit Quick Start Guide 11 Figure 3 5 Insert the Main unit 6 Use the hexagon wrench in the package fix the cover onto the frame Figure 3 6 Fix the Cover 3 2 2 One Module Flush Mounting Ga...

Страница 19: ...Video Intercom Main Unit Quick Start Guide 12 Figure 3 7 Front and Side View Figure 3 8 Appearance Description The dimension of one module gang box is 115 L 134 W 56 D mm...

Страница 20: ...of cables left outside is 100 mm Figure 3 9 Cave the Installation Hole 8 Remove the plastic sheet in the cable entry 9 Insert the gang box into the hole and pull out the cables through the cable entr...

Страница 21: ...s with tool after concrete is dry Figure 3 12 Remove the Mounting Ears 13 Insert the mounting frame together with the locating plates into the hole and fix it with 4 expansion bolts 14 Connect the cab...

Страница 22: ...Video Intercom Main Unit Quick Start Guide 15 Figure 3 14 Fix the Cover 3 3 Two Module Installation 3 3 1 Two Module Surface Mounting Mounting Frame...

Страница 23: ...e only The actual size can be slightly different from the theoretical dimension Steps 1 Paste the installation Sticker 1 onto the wall Make sure the sticker is placed leveled via measuring with the gr...

Страница 24: ...sticker and insert the expansion sleeves into the screw holes 4 Fix the mounting frame onto the wall with 4 expansion bolts Figure 3 17 Fix the Mounting Frame The mounting frame should be placed exac...

Страница 25: ...o the upper grid Figure 3 18 Placement of Lines 6 Connect the cables and module connecting line to the corresponding interfaces of the main unit then place the main unit into the upper grid Connect th...

Страница 26: ...de 19 Figure 3 19 Line Connection Effect Picture 7 Insert the modules in to the frame after wiring Main unit must be placed in the top grid Figure 3 20 Insert the Modules 8 Use the hexagon wrench in t...

Страница 27: ...Video Intercom Main Unit Quick Start Guide 20 Figure 3 21 Fix the Cover 3 3 2 Two Module Flush Mounting Gang Box Figure 3 22 Front and Side View...

Страница 28: ...237 L 134 W 56 D mm The dimensions above are for reference only The actual size can be slightly different from the theoretical dimension Steps 1 Cave the installation hole and pull the cable out The...

Страница 29: ...x into the hole and pull out the cables through the cable entry Mark the screw holes position with a marker and take out the gang box Figure 3 25 Mark the Screw Holes 4 Chisel 4 holes with drill align...

Страница 30: ...unting ears with tool after concrete is dry Figure 3 27 Remove the Mounting Ears 7 Connect wires and insert the modules a Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the...

Страница 31: ...ct Wires and Insert Modules Cable 1 refers to the cables pulled out from the wall that connected to the main unit Cable 2 refers to the module connecting line in the accessory package 8 Use the hexago...

Страница 32: ...D mm The dimensions above are for reference only The actual size can be slightly different from the theoretical dimension Steps 1 Paste the installation Sticker 1 onto the wall Make sure the sticker...

Страница 33: ...sticker and insert the expansion sleeves into the screw holes 4 Fix the mounting frame onto the wall with 4 expansion bolts Figure 3 32 Fix the Mounting Frame The mounting frame should be placed exac...

Страница 34: ...Video Intercom Main Unit Quick Start Guide 27 5 Thread the module connecting lines across the thread holes of the frame Pass the main unit connecting lines across the thread hole to the top grid...

Страница 35: ...he corresponding interfaces of the main unit then place the main unit into the upper grid Connect the other end of the module connecting line1 to the input interface of the sub module Connect two sub...

Страница 36: ...Intercom Main Unit Quick Start Guide 29 Figure 3 34 Line Connection Effect Picture 7 Insert the modules in to the frame after wiring Main unit must be placed in the top grid Figure 3 35 Insert the Mo...

Страница 37: ...Video Intercom Main Unit Quick Start Guide 30 8 Use the hexagon wrench in the package fix the cover onto the frame Figure 3 36 Fix the Cover 3 4 2 Three Module Flush Mounting Gang Box...

Страница 38: ...Video Intercom Main Unit Quick Start Guide 31 Figure 3 37 Front and Side View...

Страница 39: ...38 8 L 134 W 56 D mm The dimensions above are for reference only The actual size can be slightly different from the theoretical dimension Steps 1 Cave the installation hole and pull the cable out The...

Страница 40: ...x into the hole and pull out the cables through the cable entry Mark the screw holes position with a marker and take out the gang box Figure 3 40 Mark the Screw Holes 4 Chisel 4 holes with drill align...

Страница 41: ...ct wires and insert the modules a Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit then place the Main Unit into the upper grid b Connect the other end of Cable...

Страница 42: ...ert Modules Cable 1 refers to the cables pulled out from the wall that connected to the main unit Cable 2 and Cable 3 refer to the module connecting line in the accessory package 8 Use the hexagon wre...

Страница 43: ...on of three module mounting frame is 320 8 L 107 W 32 7 D mm The dimensions above are for reference only The actual size can be slightly different from the theoretical dimension Steps 1 Paste two Stic...

Страница 44: ...ft sticker Figure 3 46 Chisel Screw Hole 4 Remove the stickers and insert the expansion sleeves into the screw holes 5 Thread the module connecting line 400 mm and grounding line across the thread hol...

Страница 45: ...The green yellow line in the package is for grounding 6 Fix the mounting frame onto the wall with 8 expansion bolts Figure 3 48 Fix the Mounting Frame The mounting frame should be placed exactly as be...

Страница 46: ...be placed as below Figure 3 49 Placement of Lines 8 Connect the cables and module connecting line 1 to the corresponding interfaces of the main unit then place the main unit into the upper grid Connec...

Страница 47: ...Video Intercom Main Unit Quick Start Guide 40 Figure 3 50 Line Connection Effect Picture 9 Insert the modules in to the frame after wiring Main unit must be placed in the top grid on the left...

Страница 48: ...ide 41 Figure 3 51 Insert the Modules 10 Pull the grounding line out and fixed its two end to the screw on the cover Figure 3 52 Connect the Grounding Line to the Cover 11 Use the hexagon wrench in th...

Страница 49: ...Video Intercom Main Unit Quick Start Guide 42 Figure 3 53 Fix the Cover 3 5 2 More than Three Module Flush Mounting Gang Box...

Страница 50: ...Video Intercom Main Unit Quick Start Guide 43 Figure 3 54 Front and Side View...

Страница 51: ...e gang box is 338 8 L 134 W 56 D mm The dimensions above are for reference only The actual size can be slightly different from the theoretical dimension Steps 1 Cave the installation hole and pull the...

Страница 52: ...56 Cave the Installation Hole 2 Connect the two gang boxes as the below Figure 3 57 Cave the Installation Hole 3 Remove the plastic sheet of the cable entry which will be used 4 Remove the plastic she...

Страница 53: ...ables through the cable entry Mark the screw holes position with a marker and take out the gang boxes Figure 3 59 Mark the Screw Holes 6 Chisel 8 holes with drill align to marks on the wall and insert...

Страница 54: ...igure 3 60 Fix the Gang Boxes 8 Fill and level up the gap between the gang box and wall with concrete Remove the mounting ears with tool after concrete is dry Figure 3 61 Remove the Mounting Ears 9 Pa...

Страница 55: ...le 2 to the corresponding interfaces of the Main Unit then place the Main Unit into the upper grid of the left gang box b Connect the other end of Cable 2 to the input interface of Sub Module 1 Connec...

Страница 56: ...Video Intercom Main Unit Quick Start Guide 49 Figure 3 63 Install Mounting Frames The cables connect to each module shown as below Figure 3 64 Install Mounting Frames...

Страница 57: ...4 is the module connecting line 400 mm in the package Main unit must be put in the top grid 11 Pull the grounding line out and fixed its two end to the screw on the cover Figure 3 65 Connect the Grou...

Страница 58: ...and operate the video intercom devices via NVMS7000 Default parameters of door station are as follows Default IP Address 192 0 0 65 Default Port No 8000 Default User Name admin Steps 1 Run NVMS7000 en...

Страница 59: ...tivate the device When the device is not activated the basic operation and remote operation of device cannot be performed You can hold the Ctrl or Shift key to select multiple devices in the online de...

Страница 60: ...tion is 192 0 0 65 After editing the network parameters of device you should add the devices to the device list again 4 3 Add Device To configure the device remotely you need to add the device to NVMS...

Страница 61: ...dded to the client check it in the Device for Management area 4 4 Call Resident You can call residents via the door station 4 4 1 Dial via Main Unit Steps 1 Select device click Remote Configuration 2...

Страница 62: ...Video Intercom Main Unit Quick Start Guide 55 3 Enter the Room No of the indoor station which the main unit connected to You can call corresponding resident by press the call button on the main unit...

Отзывы: