REPLACEMENT PARTS 

 

ITEM NO. 

DESCRIPTION 

STOCK NO. 

MFG NO. 

MANUFACTURER 

CONDENSING UNIT 

311937 

AE2420-AA1BXM 
(BOM-2E294-1) 

TECUMSEH 

1A 

CONDENSING UNIT 

311936 

AE2415Z-AA1ASC 
(BOM-32F328-59S) 

TECUMSEH 

COMPRESSOR 
AE2420Z-DS1B 

311937 

AE1322E-679-J7 

TECUMSEH 

2A 

COMPRESSOR AE2415-
AA1A 

311936 

BM AE1157E-679-J7 

TECUMSEH 

PRESSURE CONTROL 

280610 

012-4834-000 

RANCO 

DIGITAL PRESSURE 
CONTROL 

311938 

TECUMSEH 
P/N-900-11968 

DIXELL 

FILTER DRIER 

282310 

C-052-S-T-HH 

SPORLAN 

SIGHT GLASS 

282400 

SA-12S 

SPORLAN 

ACCUMULATOR  

281700 

3616 

REFRIG. 
RESEARCH 

8A 

ACCUMULATOR 

 

102-10034 

TECUMSEH 

TXV-507 

282572 

Y1017-FP-1/6ZP 

SPORLAN 

9A 

TXV-449 

282586 

EFD-1/5-ZP 2SX4 ODF 30 

SPORLAN 

10 

LIQUID LINE SOLENOID 

281610 

E3S120W 

SPORLAN 

 

12 

ROCKER SWITCH 2PL-
20A/277V 

335917 

TIGK721-6S-BL-NBL-
20A/277V 

CARLING 

Содержание DI-FT Series

Страница 1: ...OPERATION MAINTENANCE MANUAL CUSTOM FABRICATORS OF FOODSERVICE EQUIPMENT 1947 Bill Casey Parkway Jonesboro GA 30236 Tel 1 888 584 2722 Fax 1 770 471 3715 www lowtempind com DI FT FT SERIES FROST TOP S...

Страница 2: ...SPECTION 3 SAFETY PRECAUTIONS 3 INSTALLATION INSTRUCTIONS 5 OPERATING INSTRUCTIONS 6 START UP 6 OPERATION 7 CLEANING INSTRUCTIONS 10 PREVENTATIVE MAINTENANCE 11 TROUBLESHOOTING 12 REPLACEMENT PARTS 13...

Страница 3: ...and operating Below are the precautions that are explained in more detail Please read carefully DANGER Danger warns of imminent hazard which will result in serious injury or death WARNING Warning indi...

Страница 4: ...must be mounted on a vertical surface wall and installed in the vertical position Mounting control panel in the horizontal position may result in collection of liquids and lead to electrical shock Tu...

Страница 5: ...requirements When installed adequate air flow must be provided to ensure proper operation Thru air flow is required but if not exhaust fans should be used to ensure adequate heat exhaust Connect the...

Страница 6: ...e controls Energize the unit by attaching the plug to an appropriate electrical supply 115 vac 60 hz single phase 12 amp and turning on the service switch located in the compressor compartment Prep th...

Страница 7: ...ressure control physically located in the front of the compressor compartment is used to cycle off the compressor The low pressure control should not be adjusted from the factory settings Adjustment o...

Страница 8: ...value DOWN To see the dLt temperature in programming mode it browses the parameter codes or decrease the displayed value SERVICE To enter the service menu ALARM MENU To enter the Alarm menu How to Mod...

Страница 9: ...ONTACT ACTION CONTROL LOW PRESS SIDE OPEN ON LOW CLOSE ON HIGH SAFETY HIGH PRESS SIDE CLOSE ON HIGH OPEN ON LOW LOW PRESSURE SIDE CUT IN SETTING RANGE 10 MERCURY VAC TO 100 PSI DIFFERENTIAL 10 TO 40 P...

Страница 10: ...that contain alkaline alkaline chlorinated or non chloride chemicals CONDENSER COIL WARNING Always disconnect power before inspecting or cleaning condenser coil Never use high pressure water to clean...

Страница 11: ...as adequate air flow to prevent overheating Thru air flow is required but if not exhaust fans should be used to ensure adequate heat exhaust Properly shrouding condenser inlet air flow is recommended...

Страница 12: ...ACE PROTECTOR THERMOSTAT DIFFERENTIAL SET TO CLSE WIDEN HIGH PRESSURE CUT OUT DUE TO INSUFFICIENT AIR OVERCHARGE OR AIR IN SYSTEM REDUCE REFRIGERANT CHARGE PURGE CHECK AIR SUPPLY TO CONDENSER REDUCE R...

Страница 13: ...57E 679 J7 TECUMSEH 4 PRESSURE CONTROL 280610 012 4834 000 RANCO 5 DIGITAL PRESSURE CONTROL 311938 TECUMSEH P N 900 11968 DIXELL 6 FILTER DRIER 282310 C 052 S T HH SPORLAN 7 SIGHT GLASS 282400 SA 12S...

Страница 14: ...14 DIAGRAMS DI FT WIRING DIAGRAM WIRING DIAGRAM FOR DI FT REFRIGERATION UNIT WITH MECHANICAL PRESSURE CONTROL NOTE ALL COMPONENTS TO BE GROUNDED...

Страница 15: ...15 DI FT WIRING DIAGRAM DIGITAL PRESSURE CONTROL WIRING DIAGRAM FOR DI FT REFRIGERATION UNIT WITH DIGITAL PRESSURE CONTROL NOTE ALL COMPONENTS TO BE GROUNDED NOTE ALL COMPONENTS TO BE GROUNDED...

Страница 16: ...16...

Страница 17: ...17 BLACK WHITE...

Страница 18: ...18...

Страница 19: ...ranty includes travel time to portal not to exceed 100 miles round trip or two hours total travel time The warranty requires that all labor must be performed during regular work hours Overtime premium...

Отзывы: