model
dimeNsioNs
(lxwxh)
VoltaGe
iNput fReQueNcy wattaGe waVeleNGth
(nm)
peaK
waVeleNGth
uV
spectRal
iRRadiaNce
uV
spectRal
fluX
N.w.
IND-200W-UVC
300x300x815mm
120-227V
2.2A
50/60HZ
210W
253.7nm-400nm
253.7nm
947.3µw/cm
2
48W
8.7kg
IND-200W-UVC-O
300x300x815mm
120-227V
2.2A
50/60HZ
210W
185nm-400nm
253.7nm
947.3µw/cm
2
48W
8.7kg
IND-250W-UVC
300x300x815mm
120-227V
2.6A
50/60HZ
260W
253.7nm-400nm
253.7nm
1200µw/cm
2
62W
8.7kg
IND-250W-UVC-O
300x300x815mm
120-227V
2.6A
50/60HZ
260W
185nm-400nm
253.7nm
1200µw/cm
2
62W
8.7kg
IND-300W-UVC
300x300x884mm
120-227V
3.2A
50/60HZ
310W
253.7nm-400nm
253.7nm
1300µw/cm
2
94W
9.6kg
IND-300W-UVC-O
300x300x884mm
120-227V
3.2A
50/60HZ
310W
185nm-400nm
253.7nm
1300µw/cm
2
94W
9.6kg
IND-400W-UVC
300x300x1080mm
120-227V
4.2A
50/60HZ
420W
253.7nm-400nm
253.7nm
1515µw/cm
2
116W
11.3kg
IND-400W-UVC-O
300x300x1080mm
120-227V
4.2A
50/60HZ
420W
185nm-400nm
253.7nm
1515µw/cm
2
116W
11.3kg
specificatioNs
disiNfectioN
poweR
Room aRea
RecommeNded
disiNfectioN
time
RecommeNded
VeNtilatioN time
oZoNe
oZoNe fRee
200W
<100m
2
30 min
30 min
20 min
250W
<150m
2
30 min
30 min
20 min
300W
<200m
2
30 min
30 min
20 min
400W
<250m
2
30 min
30 min
20 min
Ambient temperature 0-50˚C
oZoNe coNteNt test
•
General health standards suggest that people should not be in indoor areas with an ozone content of 0.04 ppm (parts per million).
•
It is important to properly ventilate the area post sterilisation to reduce the ozone content. See the DISINFECTION TIME AND
RELATIVE AREA table below for guidelines.
•
The ozone content in the air is influenced by ambient temperature, humidity and atmospheric pressure. See the OZONE CONTENT
TEST below which was compiled in a relative space and environment, and the data is for reference only.
•
An ozone content of 1ppm in the air equals 2.144mg/m
3
.
•
During sterilisation with the ozone version of the UV sterilisation unit, the ozone level will increase as long as the unit is operational.
For greater sterilisation of a given area, the unit may be used for longer than 30 minutes, as long as proper ventilation is done afterwards.
The INLED™ UV steriliser unit with the optional ozone wavelength lamp provides additional sterilisation through the sterilising action
of ozone (O
3
).
model
wattaGe
testiNG meteR/ Room
oZoNe coNteNt
afteR 30 miNutes
steRilisatioN
oZoNe coNteNt
afteR 30 miNutes
VeNtilatioN
UVL-200W-UVC
200W
EST-101 Ozone Meter
Temperature-Humidity Meter
Testing Room 135.2m2
(7.45m x 6.6m x 2.75m)
Enclosed room for 30 minutes
Temperature 30˚C, Humidity 87%
Atmospheric Pressure 1004.7hpa
1ppm
2.144mg/m
3
0.078ppm
0.167mg/m
3
UVL-250W-UVC-O
250W
1.5ppm
3.216mg/m
3
0.08ppm
0.17mg/m
3
UVL-300W-UVC-O
300W
1.8ppm
3.86mg/m
3
0.08ppm
0.17mg/m
3
UVL-400W-UVC-O
400W
2.6ppm
5.58mg/m
3
0.08ppm
0.17mg/m
3
disiNfectioN time aNd RelatiVe aRea