LST IND-200W-UVC Скачать руководство пользователя страница 3

model

dimeNsioNs

(lxwxh)

VoltaGe

iNput fReQueNcy wattaGe waVeleNGth 

(nm)

peaK  

waVeleNGth

uV

spectRal

iRRadiaNce

uV

spectRal

fluX

N.w.

IND-200W-UVC

300x300x815mm

120-227V

2.2A

50/60HZ

210W

253.7nm-400nm

253.7nm

947.3µw/cm

2

48W

8.7kg

IND-200W-UVC-O

300x300x815mm

120-227V

2.2A

50/60HZ

210W

185nm-400nm

253.7nm

947.3µw/cm

2

48W

8.7kg

IND-250W-UVC

300x300x815mm

120-227V

2.6A

50/60HZ

260W

253.7nm-400nm

253.7nm

1200µw/cm

2

62W

8.7kg

IND-250W-UVC-O

300x300x815mm

120-227V

2.6A

50/60HZ

260W

185nm-400nm

253.7nm

1200µw/cm

2

62W

8.7kg

IND-300W-UVC

300x300x884mm

120-227V

3.2A

50/60HZ

310W

253.7nm-400nm

253.7nm

1300µw/cm

2

94W

9.6kg

IND-300W-UVC-O

300x300x884mm

120-227V

3.2A

50/60HZ

310W

185nm-400nm

253.7nm

1300µw/cm

2

94W

9.6kg

IND-400W-UVC

300x300x1080mm

120-227V

4.2A

50/60HZ

420W

253.7nm-400nm

253.7nm

1515µw/cm

2

116W

11.3kg

IND-400W-UVC-O

300x300x1080mm

120-227V

4.2A

50/60HZ

420W

185nm-400nm

253.7nm

1515µw/cm

2

116W

11.3kg

specificatioNs

disiNfectioN 

poweR

Room aRea

RecommeNded 

disiNfectioN 

time

RecommeNded

VeNtilatioN time

oZoNe

oZoNe fRee

200W

<100m

2

30 min

30 min

20 min

250W

<150m

2

30 min

30 min

20 min

300W

<200m

2

30 min

30 min

20 min

400W

<250m

2

30 min

30 min

20 min

Ambient temperature 0-50˚C

oZoNe coNteNt test

• 

General health standards suggest that people should not be in indoor areas with an ozone content of 0.04 ppm (parts per million).

• 

It is important to properly ventilate the area post sterilisation to reduce the ozone content. See the DISINFECTION TIME AND 
RELATIVE AREA table below for guidelines.

• 

The ozone content in the air is influenced by ambient temperature, humidity and atmospheric pressure. See the OZONE CONTENT 
TEST below which was compiled in a relative space and environment, and the data is for reference only.

• 

An ozone content of 1ppm in the air equals 2.144mg/m

3

.

• 

During  sterilisation  with  the  ozone  version  of  the  UV  sterilisation  unit,  the  ozone  level  will  increase  as  long  as  the  unit  is  operational.  
For greater sterilisation of a given area, the unit may be used for longer than 30 minutes, as long as proper ventilation is done afterwards.

The INLED™ UV steriliser unit with the optional ozone wavelength lamp provides additional sterilisation through the sterilising action 
of ozone (O

3

).

model

wattaGe

testiNG meteR/ Room

oZoNe coNteNt  

afteR 30 miNutes 

steRilisatioN

oZoNe coNteNt  

afteR 30 miNutes 

VeNtilatioN

UVL-200W-UVC

200W

EST-101 Ozone Meter

Temperature-Humidity Meter

Testing Room 135.2m2

(7.45m x 6.6m x 2.75m)

Enclosed room for 30 minutes

Temperature 30˚C, Humidity 87%

Atmospheric Pressure 1004.7hpa

1ppm

2.144mg/m

3

0.078ppm

0.167mg/m

3

UVL-250W-UVC-O

250W

1.5ppm

3.216mg/m

3

0.08ppm

0.17mg/m

3

UVL-300W-UVC-O

300W

1.8ppm

3.86mg/m

3

0.08ppm

0.17mg/m

3

UVL-400W-UVC-O

400W

2.6ppm

5.58mg/m

3

0.08ppm

0.17mg/m

3

disiNfectioN time aNd RelatiVe aRea