Basic Functions
78
7.2 Multi-Step Frequency setting
Group
Code
Parameter Name
Setting
Range Default Unit
Drive group
0.0
[Frequency Command]
5.0
0 - 400
0.00
Hz
Frq
[Frequency Mode]
0
0 - 8
0
-
St1
[Multi-Step frequency 1]
-
0 - 400
10.00
Hz
St2
[Multi-Step frequency 2]
-
20.00
St3
[Multi-Step frequency 3]
-
30.00
I/O group
I18
[Multi-function input terminal
P2 define]
5
0 - 30
1
-
I19
[Multi-function input terminal
P3 define]
6
2
-
I20
[Multi-function input terminal
P4 define]
7
3
-
I30
[Multi-Step frequency 4]
-
0 - 400
30.00
Hz
I31
[Multi-Step frequency 5]
-
25.00
I32
[Multi-Step frequency 6]
-
20.00
I33
[Multi-Step frequency 7]
-
15.00
Select a terminal to give Multi-step frequency command among P1-P4 terminals.
If terminals P2-P4 are selected, set I18-I20 to 5-7 to give Multi-step frequency
command.
Multi-step frequency 0 is settable in Frq
– [Frequency mode] and 0.00 – [Frequency
command].
Multi-step frequency 1-3 are set at St1-St3 in Drive group, while Step frequency 4-7 are
set at I30-I33 in I/O group.
Step
freq.
FX or
RX
P4
P3
P2
0
-
-
-
1
-
-
2
-
-
3
-
4
-
-
5
-
6
-
7
www.barghmaher.ir
Содержание iG5H Series
Страница 13: ...www barghmaher ir ...
Страница 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Страница 23: ...10 Installation Wiring www barghmaher ir ...
Страница 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Страница 173: ...Protective functions 160 www barghmaher ir ...
Страница 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Страница 223: ...210 www barghmaher ir ...
Страница 225: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 www barghmaher ir ...