77
Basic Functions
Bas
ic
Fun
ctio
ns
Frequency setting via Digital Volume (up-down)
7.1.9
Group
Code
Parameter Name
Setting
Range Default
Unit
Drive
group
0.0
[Frequency Command]
-
0 -400
0.00
Hz
Frq
[Frequency Mode]
8
0 - 8
0
Select 7 in Frq code of Drive group.
Related code: I 59, I 60, I 61
Refer to Chapter 11. RS485 communication.
Analog Hold
7.1.10
Group
Code
Parameter Name
Setting
Range Default
Unit
Drive
group
Frq
[Frequency Mode]
2 - 7
0 - 8
0
I/O
group
I17
[Multi-function input terminal P1
define]
-
0 -25
0
-
-
I20
[Multi-function input terminal
P4 define]
30
3
It is available when Frq code setting is 2 - 7.
Select one terminal to use for Analog Hold command among Multi-function input
terminal (P1 - P4).
►
When P4 terminal is selected,