LSI MegaRAID SAS 9240-4i Скачать руководство пользователя страница 2

2 of 4

Figure 1 Layout of the MegaRAID SAS 9240-4i 

RAID Controller

Table 1

 describes the jumpers and the connectors 

on the SAS 9240-4i RAID controller.

Table 1

SAS 9240-4i Jumpers and Connectors

Figure 2

 shows the location of the jumpers and the 

connectors on the SAS 9240-8i RAID controller.

Figure 2 Layout of the MegaRAID SAS 9240-8i 

RAID Controller

Table 2

 describes the jumpers and the connectors 

on the SAS 9240-8i RAID controller.

Table 2

SAS 9240-8i Jumpers and Connectors

Step 4

Install the RAID Controller

Insert the RAID controller in a PCI Express slot 
on the motherboard, as shown in 

Figure 3

. Press 

down gently, but firmly, to seat the card correctly 

Jumper/
Connector Type

Description

J1

RISCwatch header

16-pin header 

Reserved for LSI use.

J2

CPLD header

10-pin header

Reserved for LSI use.

J3

External LED drive 
activity/fault header

4-pin connector

Connects to external, green or red 
LEDs that indicate drive activity or 
faults.

J4

x4 Mini-SAS (SFF-
8087) Ports 0–3 
internal connector

Connects the cables from the 
controller to SAS drives or SATA II 
drives, or a SAS expander.

J6

PCI Express x8 
board edge 
connector

x8 interface that provides 
connections on both the top and 
the bottom of the board.

TP1

Universal Asyn-
chronous Receiver/
Transmitter (UART) 
debugging

4-pin connector

Reserved for LSI use.

U2

MegaRAID Skinny 
1-wire connector

2-pin connector

To create a RAID 5 configuration, 
you have to plug a 1-wire key into 
this connector. Refer to the 

MegaRAID 6Gb/s SAS RAID 
Controllers User’s Guide

 for more 

information.

Jumper/
Connector Type

Description

J1

RISCwatch header

16-pin header 

Reserved for LSI use.

J2

CPLD header

10-pin header

Reserved for LSI use.

J3

External LED drive 
activity/fault header

4-pin connector

Connects to external, green or red 
LEDs that indicate drive activity or 
faults.

J4

x4 Mini-SAS (SFF-
8087) Ports 0–3 
internal connector

Connects the cables from the 
controller to SAS drives or SATA II 
drives, or a SAS expander.

J5

x4 Mini-SAS (SFF-
8087) Ports 4–7 
internal connector

Connects the cables from the 
controller to SAS drives or SATA II 
drives, or a SAS expander.

J6

PCI Express x8 
board edge 
connector

x8 interface that provides 
connections on both the top and 
the bottom of the board.

TP1

Universal Asyn-
chronous Receiver/
Transmitter (UART) 
debugging

4-pin connector

Reserved for LSI use.

U2

MegaRAID Skinny 
1-wire connector

2-pin connector

To create a RAID 5 configuration, 
you have to plug a 1-wire key into 
this connector. Refer to the 

MegaRAID 6Gb/s SAS RAID 
Controllers User’s Guide

 for more 

information.

J4

J2

J6

85043-00

J5

J3

Содержание MegaRAID SAS 9240-4i

Страница 1: ... Note SATA II is the only type of SATA supported by these RAID controllers R A I D C O N T R O L L E R I N S TA L L AT I O N Step 1 Unpack the RAID Controller Unpack the RAID controller in a static free environment Remove it from the antistatic bag and inspect it for damage If the RAID controller appears to be damaged or if the MegaRAID Universal Software Suite CD is missing contact LSI or your Me...

Страница 2: ...and the bottom of the board TP1 Universal Asyn chronous Receiver Transmitter UART debugging 4 pin connector Reserved for LSI use U2 MegaRAID Skinny 1 wire connector 2 pin connector To create a RAID 5 configuration you have to plug a 1 wire key into this connector Refer to the MegaRAID 6Gb s SAS RAID Controllers User s Guide for more information Jumper Connector Type Description J1 RISCwatch header...

Страница 3: ... it is turned on to the devices the computer might not recognize the devices The firmware takes several seconds to initialize During this time the controller scans the ports Step 8 Run the WebBIOS Configuration Utility Run the WebBIOS Configuration Utility to configure the groups and the virtual drives When the message Press Ctrl H for WebBIOS appears on the screen immediately press CTRL H to run ...

Страница 4: ... single span RAID 5 drive striping with distributed parity Data is striped across all drives in the group Part of the capacity of each drive stores parity information that reconstructs data if a drive fails RAID 5 provides good data throughput for applications with high read request rates RAID 10 RAID 1 and RAID 0 in spanned groups RAID 10 uses mirrored pairs of drives to provide complete data red...

Отзывы: