LSI MegaRAID SAS 84016E Скачать руководство пользователя страница 4

PN: 80-00141-01 Rev. B, April 2007

Find a list of LSI Logic Corporation’s U.S. distributors, international distributors, 
sales offices, and design resource centers on the LSI Logic web site at:

http://www.lsilogic.com/contacts/index.html

LSI Logic, the LSI Logic logo design, and MegaRAID are registered trademarks of 
LSI Logic Corporation. All other brand and product names may be trademarks of 
their respective companies.

®

Copyright © 2006 - 2007 by LSI Logic Corporation. All rights reserved.

LSI Logic products are not intended for use in life-support appliances, devices, or 
systems. Use of any LSI Logic product in such applications without written consent 
of the appropriate LSI Logic officer is prohibited. 

Purchase of I

2

C components of LSI Logic Corporation, or one of its sublicensed 

Associated Companies, conveys a license under the Philips I

2

C Patent Rights to 

use these components in an I

2

C system, provided that the system conforms to the 

I

2

C standard Specification as defined by Philips.

LSI Logic Corporation reserves the right to make changes to any products and 
services herein at any time without notice. LSI Logic does not assume any 
responsibility or liability arising out of the application or use of any product or 
service described herein, except as expressly agreed to in writing by LSI Logic; nor 
does the purchase, lease, or use of a product or service from LSI Logic convey a 
license under any patent rights, copyrights, trademark rights, or any other of the 
intellectual property rights of LSI Logic or of third parties. 

S U P P O R T E D   R A I D   L E V E L S

The SAS 84016E supports disk arrays using the following 
RAID levels:

RAID 0 (Data striping):

 Data is striped across all disks 

in the array, enabling very fast data throughput. There is 
no data redundancy. All data is lost if any disk fails.

RAID 1 (Disk mirroring):

 Data is written simultaneously 

to two disks, providing complete data redundancy if one 
disk fails. The maximum array capacity is equal to the 
available size of the smaller of the two hard drives.

RAID 5 (Disk striping with distributed parity):

 Data is 

striped across all disks in the array. Part of the capacity 
of each disk stores parity information that reconstructs 
data if a disk fails. Provides good data throughput for 
applications with high read request rates.

RAID 10 (RAID 1 and RAID 0 in spanned arrays):

 Uses 

mirrored pairs of disks to provide complete data 
redundancy. Provides high data throughput rates.

RAID 50 (RAID 5 and RAID 0 in spanned arrays):

 Uses 

both parity and disk striping across multiple disks to 
provide complete data redundancy. Provides high data 
throughput rates.

T E C H N I C A L   S U P P O R T

For assistance in installing, configuring, or running the SAS 
84016E, contact LSI Logic Technical Support:

E-mail: 

[email protected]

[email protected] (Europe)

Phone Support: 

1-800-633-4545 (North America)

+44 1344 413 441 (Europe)

Web Site:

 

http://www.lsilogic.com/support/

 

Отзывы: