LSI LumeLEX 2030 Series Скачать руководство пользователя страница 5

 

 
www.LightingServicesInc.com 

Page 5 of 6 

IS-0139_A 

 
 

Aiming the 
Self-
Locking 
and 
Wrench-
Locking 
Fixtures 

Before Aiming: 

For self-locking, you do not need 

an external locking device to set the horizontal and 
vertical focus. For wrench locking, use the 
supplied Allen key (3/32 inches) to set and lock the 
horizontal and vertical focus.

 

STEP 

ACTION  

Turn off all power to the fixture, 
including the fixture switch on the 
fitting, and let the lamp cool. 

WARNING: LED and fixture may be 
hot. 

Do you want to aim the fixture 
horizontally or vertically? 

 

For horizontal aiming,

 hold the 

lamp housing and turn it left or 
right until you achieve your desired 
orientation (

Fig. 12

). 

 

For vertical aiming,

 hold the lamp 

housing and angle it up and down 
until you achieve your desired 
orientation (

Fig. 13

). 

 

For wrench locking: 

After aiming, 

insert the Allen key into the 
horizontal or vertical focus lock 
(

Fig. 14

), and turn it clockwise to 

tighten. 

Note:

 Allen key is supplied for track 

and busway fixtures.  It is stored in 
fitting handle (

Fig. 15

). 

Restore power. 

WARNING: Do not look directly at 
the lit LED. 

 

 

Figure 15. Allen key storage in fitting.

 

  Push in to secure the key. 

 

 

Figure 12. Turn fixture left or right to set the 
horizontal focus. 

 

 

Figure 13. Angle fixture up or down to set the 
vertical focus. 

 

 

Figure 14. Horizontal focus lock (L). Vertical 
focus lock (R). 

 

 

Pull to remove 

Push to store