A-6

Glossary of Terms and Abbreviations

SCSI Bus

A host adapter and one or more SCSI peripherals connected by cables
in a linear chain configuration. The host adapter may exist anywhere on
the chain, allowing connection of both internal and external SCSI
devices. A system may have more than one SCSI bus by using multiple
host adapters.

SCSI Device

Any device that conforms to the SCSI standard and is attached to the
SCSI bus by a SCSI cable. This includes SCSI host adapters and SCSI
peripherals.

SCSI ID

A way to uniquely identify each SCSI device on the SCSI bus. Each
SCSI bus has eight available SCSI IDs numbered 0 through 7 (or 0
through 15 for Wide SCSI). The host adapter usually gets the highest ID,
(7 or 15) giving it priority to control the bus.

SDMS

Storage Device Management System. An LSI Logic software product that
manages SCSI system I/O.

Single-Ended
SCSI

A hardware specification for connecting SCSI devices. It references each
SCSI signal to a common ground. This is the most common method (as
opposed to differential SCSI which uses a separate ground for each
signal).

STA

SCSI Trade Association. A group of companies that cooperate to
promote SCSI parallel interface technology as a viable mainstream I/O
interconnect for commercial computing.

Synchronous
Data Transfer

One of the ways data is transferred over the SCSI bus. Transfers are
clocked with fixed-frequency pulses. This is faster than asynchronous
data transfer. Synchronous data transfers are negotiated between the
SCSI host adapter and each SCSI device.

System BIOS

Controls the low level POST (Power-On Self-Test), and basic operation
of the CPU and computer system.

Ultra SCSI

A standard for SCSI data transfers. It allows a transfer rate of up to
20 Mbytes/s over a 8-bit SCSI bus and up to 40 Mbytes/s over a 16-bit
SCSI bus. STA (SCSI Trade Association) supports using the term “Ultra
SCSI” over the older term “Fast-20”.

Ultra2 SCSI

A standard for SCSI data transfers. It allows a transfer rate of up to
40 Mbytes/s over an 8-bit SCSI bus, and up to 80 Mbytes/s over a

Содержание LSI8751D

Страница 1: ...LSI8751D PCI to SCSI Host Adapter USER S GUIDE Au g u s t 2 0 0 1 Version 3 0...

Страница 2: ...the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shielded cables...

Страница 3: ...make changes to any products herein at any time without notice LSI Logic does not assume any responsibility or liability arising out of the application or use of any product described herein except a...

Страница 4: ...iv...

Страница 5: ...al Support Hot Line at 719 533 7230 The hours of operation are from 7 30 a m to 4 30 p m MST Monday through Friday Before calling please have the following information Which LSI Logic host adapter are...

Страница 6: ...Publications PCI Storage Device Management System SDMS 4 0 User s Guide Order Number S14007 A Revision Record Revision Date Remarks 1 0 6 95 Final version 2 0 3 99 Document converted to LSI format 2...

Страница 7: ...2 Inserting the Host Adapter 2 3 2 2 3 Connecting the SCSI Peripherals 2 5 2 2 4 SCSI Bus Termination 2 14 2 2 5 Setting SCSI IDs 2 19 2 3 Completing the Installation 2 21 Chapter 3 Technical Specifi...

Страница 8: ...ii Contents Appendix A Glossary of Terms and Abbreviations Customer Feedback...

Страница 9: ...ecting Additional Internal SCSI Devices 2 8 2 7 Multiple Internal SCSI Devices Chained Together 2 9 2 8 SCSI LED Connector 2 10 2 9 External Cable to Host Adapter 2 11 2 10 External Cable to External...

Страница 10: ...iv...

Страница 11: ...1 SCSI Bus Widths and Speeds 2 5 2 2 SCSI ID Record 2 20 3 1 Maximum Power Requirements 3 2 3 2 PCI Connector JI Top 3 4 3 3 PCI Connector JI Bottom 3 5 3 4 SCSI Connectors J2 and J3 3 6 3 5 LED Conne...

Страница 12: ...vi...

Страница 13: ...e LSI8751D is a 16 bit High Voltage Differential HVD Ultra SCSI solution for your computer using only one PCI slot This board can support both legacy Fast SCSI devices and the newest Ultra SCSI device...

Страница 14: ...the LSI8751D supports these features Full 32 bit DMA bus master Zero wait state bus master data bursts Universal 5 V or 3 3 V PCI bus voltage PCI Local Bus Specification Revision 2 1 compliance 1 2 2...

Страница 15: ...r dimensions 5 00 x 3 25 inches 127 X82 552 mm Universal 32 bit card edge connector 1 2 4 Ultra SCSI The LSI8751D has full support for Ultra SCSI and simultaneously supports Fast SCSI Ultra SCSI is an...

Страница 16: ...1 4 Describing the LSI8751D...

Страница 17: ...prefer more detailed guidance for installing the LSI8751D please follow the instructions in Section 2 2 Detailed Installation Procedure For safe and proper installation check the user s manual suppli...

Страница 18: ...BIOS Configuration Utility which provides a means to change system configuration 2 2 Detailed Installation Procedure This section provides step by step instructions for installing the LSI8751D and co...

Страница 19: ...e of this board Figure 2 1 Hardware Connections for the LSI8751D Step 2 Switch off and unplug power cords for all components in your system Step 3 Remove the cabinet cover on your computer to access t...

Страница 20: ...blank panel on the back of the computer aligned with the PCI slot you intend to use Save the bracket screw Step 6 Carefully insert the edge connector J1 see Figure 2 1 of the host adapter into the PC...

Страница 21: ...able are keyed to ensure proper pin 1 connection All external SCSI bus connections to the LSI8751D are made with shielded 68 conductor cables see Figure 2 3 The connectors on this cable are always key...

Страница 22: ...2 6 Installing the LSI8751D Figure 2 3 SCSI Cables SCSI Cable for Internal Connections SCSI Cable for External Connections...

Страница 23: ...making internal SCSI bus connections Step 1 To connect an internal SCSI device plug the 68 pin connector on one end of the internal SCSI ribbon cable into the connector J2 Make certain to match pin 1...

Страница 24: ...e Figure 2 5 Make sure to match pin 1 on all connections Figure 2 5 Internal SCSI Ribbon Cable to Internal SCSI Device Connection Step 3 Connect additional internal SCSI devices by using an internal S...

Страница 25: ...etailed Installation Procedure 2 9 Figure 2 7 shows an example of this type of chained connection Make sure to match pin 1 on all connections Figure 2 7 Multiple Internal SCSI Devices Chained Together...

Страница 26: ...ws the front panel LED to indicate activity on the SCSI bus Connector J4 is not keyed The orientation of the LED cable does not matter as long as all four pins are connected Figure 2 8 SCSI LED Connec...

Страница 27: ...connections Step 1 To connect external SCSI devices to the LSI8751D plug the 68 pin connector on one end of a shielded external SCSI cable see Figure 2 3 into the host adapter connector J3 see Figure...

Страница 28: ...pin connector on the other end of the shielded external SCSI cable into the SCSI connector on the external SCSI device Figure 2 10 shows an example of this connection Figure 2 10 External Cable to Ext...

Страница 29: ...ne external SCSI device to the host adapter you must chain them together with shielded external SCSI cables Figure 2 11 shows an example of these chained connections Figure 2 11 Multiple External SCSI...

Страница 30: ...l device terminators are usually set with jumpers resistor modules or a switch on the peripheral Refer to the peripheral manufacturer s instructions and to the user s manual for your computer for info...

Страница 31: ...Termination on the host adapter is required in this case Insert the plug in HVD terminator into the external connector J3 on the host adapter Figure 2 12 shows an example of how termination is determ...

Страница 32: ...ermination on the host adapter is required in this case Insert the plug in HVD terminator into the internal connector J2 on the host adapter Figure 2 13 shows you how to enable or disable termination...

Страница 33: ...t terminate the last internal device and external device on the SCSI bus You must disable the termination on all other devices Termination on the host adapter is not required in this case Save the plu...

Страница 34: ...8751D Figure 2 14 Internal and External SCSI Device Termination Last Device on Chain Termination Enabled Host Adapter Termination Not Required Last Device on Chain Termination Enabled Does Not End Cha...

Страница 35: ...ur host adapter ID using the SCSI BIOS Configuration Utility The peripheral device SCSI IDs are usually set with jumpers or with a switch on the peripheral Refer to the peripheral manufacturer s instr...

Страница 36: ...2 20 Installing the LSI8751D Table 2 2 SCSI ID Record SCSI ID SCSI Device 15 14 13 11 10 9 8 7 LSI8751D default 6 5 4 3 2 1 0...

Страница 37: ...to boot up Step 4 Refer to the PCI Storage Device Management System SDMS 4 0 User s Guide or the guide for the software you plan to use to load the driver software for your particular operating syste...

Страница 38: ...2 22 Installing the LSI8751D...

Страница 39: ...FCC 3 1 1 Physical Characteristics The dimensions of the LSI8751D are 5 00 x 3 25 inches 127 x 82 552 mm PCI connection is made through the edge connector J1 Internal SCSI connection is made through t...

Страница 40: ...rent may be higher At temperatures of at least 25 C a current of 4 A is sustained no longer than 30 seconds before the self resetting TERMPWR short circuit protection device opens J3 J1 J2 J4 LSI53C87...

Страница 41: ...The bare board meets or exceeds the requirements of UL flammability rating 94 V0 The bare board is also marked with the supplier s name or trademark type and UL flammability rating Because this board...

Страница 42: ...n 12 V 1 GND 17 C_BE2 33 GND 49 TCK 2 REQ 18 GND 34 KEYWAY 50 GND 3 3 V 5 V 19 IRDY 35 KEYWAY 51 TDO 4 AD31 20 3 3 V 36 AD08 52 5 V 5 AD29 21 DEVSEL 37 AD07 53 5 V 6 GND 22 GND 38 3 3 V 54 INTB 7 AD27...

Страница 43: ...r SCSI termination power is also supplied by the board Table Table 1 4 shows the signal assignments for J2 and J3 SCSI HVD connectors Table 3 3 PCI Connector JI Bottom Signal Name1 1 Shaded signals ar...

Страница 44: ...Signal Name Pin Signal Name Pin DB 12 1 TERMPWR 18 DB 12 35 TERMPWR 52 DB 13 2 RESERVED 19 DB 13 36 RESERVED 53 DB 14 3 ATN 20 DB 14 37 ATN 54 DB 15 4 GND 21 DB 15 38 GND 55 DB P1 5 BSY 22 DB P1 39 BS...

Страница 45: ...nd control the system The SCSI BIOS on your host adapter acts as an extension of the system BIOS Bit A binary digit The smallest unit of information a computer uses The value of a bit 0 or 1 represent...

Страница 46: ...er as opposed to single ended SCSI which references each SCSI signal to a common ground Two types of differential signals in the industry are High Voltage Differential HVD and Low Voltage Differential...

Страница 47: ...system Internal SCSI Device A SCSI device installed inside the computer cabinet These devices are connected in a continuous chain using an unshielded ribbon cable IRQ Interrupt Request Channel A path...

Страница 48: ...data by more than one SCSI device This increases the data throughput NVRAM NonVolatile Random Access Memory Actually an EEPROM Electronically Erasable Read Only Memory chip used to store configuratio...

Страница 49: ...track of multiple commands that allow for increased throughput on the SCSI bus RAM Random Access Memory The computer s primary working memory in which program instructions and data are stored and are...

Страница 50: ...ces It references each SCSI signal to a common ground This is the most common method as opposed to differential SCSI which uses a separate ground for each signal STA SCSI Trade Association A group of...

Страница 51: ...n a hard disk that can be used as if it were RAM Wide SCSI A SCSI 2 feature allowing 16 bit or 32 bit transfers on the SCSI bus This dramatically increases the transfer rate over the standard 8 bit SC...

Страница 52: ...A 8 Glossary of Terms and Abbreviations...

Страница 53: ...I bus connections 2 7 L LED connector J4 3 6 LED interface 3 6 LSI8751D host adapter board characteristics 1 3 features 1 2 installing 2 2 to 2 21 termination 1 2 Ultra SCSI 1 3 O operational environm...

Страница 54: ...IX 2...

Страница 55: ...ents and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name phone number fax number and company address...

Страница 56: ...propriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additional information Excellent Good Average Fair Po...

Страница 57: ...You can find a current list of our U S distributors international distributors and sales offices and design resource centers on our web site at http www lsilogic com contacts na_salesoffices html...

Страница 58: ...ters Tokyo Japan Tel 81 3 5463 7821 Fax 81 3 5463 7820 LSI Logic Corporation North American Headquarters Milpitas CA Tel 408 433 8000 Fax 408 433 8989 LSI Logic Europe Ltd European Headquarters Brackn...