background image

Quick Hardware Setup Guide

 DB11-000045-01, May 2003

LSI Logic, the LSI Logic logo design, Integrated Mirroring, and Integrated Striping are
trademarks or registered trademarks of LSI Logic Corporation. All other brand and prod-
uct names may be trademarks of their respective companies.

You can find a list of LSI Logic Corporation’s U.S. distributors, international distributors,
sales offices, and design resource centers on the LSI Logic web site at:

http://www.lsilogic.com/contacts/index.html

Copyright © 2003 by LSI Logic Corporation. All rights reserved.

LSI Logic Corporation reserves the right to make changes to any products and services
herein at any time without notice. LSI Logic does not assume any responsibility or liabil-
ity arising out of the application or use of any product or service described herein,
except as expressly agreed to in writing by LSI Logic; nor does the purchase, lease, or
use of a product or service from LSI Logic convey a license under any patent rights,
copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic
or of third parties.

Step 5: Set Target IDs for SCSI Devices

Each connected SCSI device must have a unique Target ID (TID),
ranging from 0 to 15 for 16-bit devices. The LSI21320-R uses
TID 7, which is the highest priority TID. Verify that no two SCSI
devices on the same channel use the same TID; change the TIDs
as needed. See the SCSI device documentation for instructions
concerning changing the SCSI device’s TID.

Figure 2 Inserting the Host Bus Adapter Board

Step 6: Set SCSI Termination

The SCSI bus, which consists of the SCSI bus cables and SCSI
devices, is an electrical transmission line that must be terminated
properly to minimize signal reflections and prevent data loss.

Enable SCSI termination at each end of each SCSI bus (channel)
and only at the ends of the SCSI bus. In

Figure 3

internal SCSI

devices connect to one channel. The LSI21320-R automatically
terminates its end of the SCSI bus if only internal devices or only
external devices connect to that channel. The LSI21320-R
automatically disables termination if both internal and external
devices connect to that channel, because the LSI21320-R is then
in the “middle” of the SCSI bus.

Figure 3 SCSI Termination for Internal SCSI Devices

For a disk array, set the SCSI bus termination so that removing or
adding a SCSI device does not disturb termination. To do this,
connect the LSI21320-R to one end of the SCSI cable and connect
a SCSI terminator module at the other end of the cable. Attach
SCSI devices to the connectors between the two ends and disable
termination on them.

Figure 4

shows an external drive enclosure

with seven SCSI drives. Termination is enabled at the end of the
cable nearest the “last” SCSI drive, which is assigned TID 6.

Figure 4 SCSI Termination in a SCSI Disk Array

Some disk enclosures handle termination for the SCSI devices
within the enclosure. Refer to the enclosure documentation for
more information.

Step 7: Power Up the Computer

Replace the computer cover and connect the power cords. Turn on
the power to all the devices. Be sure the SCSI devices power up
before or at the same time as the computer. Otherwise, the
computer might not recognize the SCSI devices.

Step 8: Run the BIOS Configuration Utility

During boot, the following message appears:

Press <Ctrl-C> to start the LSI Logic Configuration Utility

When this message appears, press <Ctrl-C> to run the LSI Logic
BIOS Configuration Utility. The Fusion-MPT Device Management
User’s Guide 
provides instructions for using the LSI Logic BIOS
Configuration Utility.

Step 9: Install the Operating System Driver

LSI Logic provides device drivers for the following operating
systems:

MS-DOS version 6.xx or later

Microsoft Windows NT 4.0, Windows 2000, Windows XP, and
Windows Server 2003

Novell NetWare 5.1 and 6.0

Red Hat Linux 7.2 and 7.3

Integrated RAID

The LSI21320-R supports integrated RAID, which includes
Integrated Mirroring™ (IM) and Integrated Striping™ (IS). IM
enables mirroring of two to six drives in a disk array. IS enables
data striping across up to six drives.

J4

Internal SCSI Channel A Connector

J6

LED for SCSI Channel A and SCSI Channel B

1

1.

If the LED does not light during SCSI bus activity, disconnect the LED cable,
rotate it 180 degrees, and re-connect the LED cable to J6.

Connector

Definition

32-Bit Slots

64-Bit Slots

Bracket Screw

Termination on Controller

Enabled

SCSI Devices

(Termination Disabled on Both)

SCSI
Terminator

TID 0

TID 1

TID 2

TID 3

TID 4

TID 5

TID 6

External

SCSI Drives

Termination

Enabled

LSI21320-R

TID 7

LSI53C1030