background image

2-26

Installing the LSI21003

Содержание LSI21003

Страница 1: ...S14051 LSI21003 PCI to Dual Channel SCSI Host Adapter User s Guide O c t o b e r 2 0 0 0 Version 1 0...

Страница 2: ...t and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shielded c...

Страница 3: ...ses of this product until rescinded by an update To receive product literature visit us at http www lsilogic com LSI Logic Corporation reserves the right to make changes to any products herein at any...

Страница 4: ...iv...

Страница 5: ...30 a m to 4 30 p m MST Monday through Friday You may also send an e mail to support lsil com Before calling or sending an e mail please have the following information Which LSI Logic host adapter are...

Страница 6: ...nology that is referenced throughout this user s guide Related Publications LSI53C1010 33 PCI to Dual Channel Ultra3 SCSI Multifunction Controller Technical Manual Order Number S14025 A PCI Storage De...

Страница 7: ...21003 2 1 Quick Installation Procedure 2 1 2 2 Detailed Installation Procedure 2 3 2 2 1 Before You Start 2 3 2 2 2 Inserting the Host Adapter 2 4 2 2 3 Connecting the SCSI Peripherals 2 6 2 2 4 SCSI...

Страница 8: ...Connection 2 9 2 6 Connecting Additional Internal SCSI Devices 2 10 2 7 Multiple Internal SCSI Devices Chained Together 2 11 2 8 SCSI LED Connector 2 12 2 9 External Cable to Host Adapter 2 13 2 10 Ex...

Страница 9: ...Back Side Signals 3 6 3 4 SCSI Connector J2 Channel A Internal 3 8 3 5 SCSI Connector J3 Channel A External 3 9 3 6 SCSI Connector J4 Channel A Internal 3 10 3 7 SCSI Connector J5 Channel B Internal 3...

Страница 10: ...x Contents...

Страница 11: ...adapter Installing this host adapter in your PCI system allows connection of SCSI devices over a SCSI bus The LSI21003 provides 16 bit Low Voltage Differential LVD and Single Ended SE SCSI solutions...

Страница 12: ...ords of SCRIPTS instructions PCI Universal 3 3 V 5 V bus support Supports PCI write and invalidate read line and read multiple commands 1 2 2 SCSI Interface The SCSI interface includes these features...

Страница 13: ...utility SCSI activity connector for external LED LSI53C1010 33 PCI Dual Channel SCSI Multifunction Controller includes 8 Kbytes internal RAM per channel for SCRIPTS instruction storage 1 2 3 Board Ch...

Страница 14: ...er rate of up to 40 Mbytes s for wide Ultra SCSI transfers and the other up to 160 Mbytes s for wide Ultra160 SCSI transfers Channel A is SE only with active autosensing termination The Channel A inte...

Страница 15: ...e with on board LVD termination Table 1 1 lists standard cable specifications Table 1 1 Standard Cables Maximum Bus Length Meters1 1 This parameter may be exceeded in point to point and engineered app...

Страница 16: ...1 6 Using the LSI21003...

Страница 17: ...erienced computer user with prior host adapter installation and SCSI bus setup experience If you prefer more detailed guidance for installing the LSI21003 please follow the instructions in Section 2 2...

Страница 18: ...board with the bracket screw before making the internal and external SCSI bus connections see Figure 2 2 Step 9 If you are connecting any internal SCSI devices plug the end of an appropriate internal...

Страница 19: ...low to get an overall idea of the steps to perform Open your PC cabinet and select an open PCI slot Insert the host adapter Connect your internal and external SCSI peripherals Terminate the SCSI bus S...

Страница 20: ...er from your computer per the instructions in the user s manual for your system to access the PCI slots Make sure you are adequately grounded Step 5 Locate the slots for PCI plug in board installation...

Страница 21: ...see Figure 2 2 before making the SCSI bus connections Figure 2 1 Hardware Connections for the LSI21003 Channel B 68 Pin Internal High Density SCSI Connector J5 Channel A 68 Pin Internal High Density S...

Страница 22: ...3 are made with an unshielded 68 or 50 conductor ribbon cable see Figure 2 3 One side of this cable is marked with a color to indicate the pin 1 side The connectors on this cable are keyed to ensure a...

Страница 23: ...rthest from the host adapter All external SCSI bus connections to the LSI21003 are made with a shielded 50 pin high density cable see Figure 2 3 The connectors on this cable are always keyed to ensure...

Страница 24: ...bus connections If you have no internal devices to connect proceed to Step 4 Step 1 Plug one end of a SCSI ribbon cable into an appropriate connector J2 J4 or J5 The example in Figure 2 4 shows a wide...

Страница 25: ...nnection appears in Figure 2 5 Figure 2 5 Internal SCSI Ribbon Cable to Internal SCSI Device Connection If this is the only internal device on the bus proceed to Step 4 If you have more than one inter...

Страница 26: ...2 10 Installing the LSI21003 Step 3 Plug the cable into each additional device as illustrated in Figure 2 6 Figure 2 6 Connecting Additional Internal SCSI Devices...

Страница 27: ...Detailed Installation Procedure 2 11 An example of multiple internal SCSI devices chained together is shown in Figure 2 7 Figure 2 7 Multiple Internal SCSI Devices Chained Together...

Страница 28: ...lights when there is activity on the SCSI bus Connector J6 is not keyed The orientation of the LED cable should not matter as long as all four pins are connected If the LED does not light during SCSI...

Страница 29: ...es proceed to Section 2 2 4 SCSI Bus Termination page 2 15 To connect external SCSI devices to the LSI21003 Step 1 Plug the 50 pin HD connector on one end of a shielded external SCSI cable into the ho...

Страница 30: ...connector on the external SCSI device An example of this connection is shown in Figure 2 10 Figure 2 10 External Cable to External SCSI Device If this is the only external SCSI device on your system p...

Страница 31: ...ernal SCSI Devices Chained Together 2 2 4 SCSI Bus Termination The devices making up the SCSI bus are connected serially chained together with SCSI cables The first and last physical SCSI devices conn...

Страница 32: ...ng the same sensing method The LSI21003 senses SCSI devices by detecting the ground signal on conductor 22 of a 50 conductor internal cable conductor 36 of a 50 conductor external cable or conductor 5...

Страница 33: ...Detailed Installation Procedure 2 17 Figure 2 12 shows an example of how termination is determined for this SCSI bus configuration Figure 2 12 High Density Internal SCSI Device Termination...

Страница 34: ...external connector J3 if you use both internal connectors Figure 2 13 shows an example of how termination is determined for this SCSI bus configuration Figure 2 13 Internal and Internal SCSI Device Te...

Страница 35: ...f how termination is determined for this SCSI bus configuration on the host adapter external Channel A Figure 2 14 External SCSI Device Termination Last Device on Chain Termination Enabled Does Not En...

Страница 36: ...minate the last internal and external devices on the SCSI bus You must disable the termination on all other devices Termination on Channel A of the host adapter is automatically disabled in this case...

Страница 37: ...Installation Procedure 2 21 Figure 2 15 Internal and External SCSI Device Termination Last Device on Chain Termination Enabled Does Not End Chain Termination Disabled Last Device on Chain Termination...

Страница 38: ...OS Configuration Utility Note Devices on a narrow 8 bit bus only respond to SCSI IDs 0 7 Also they will not be able to respond to the host adapter if the host adapter ID is set higher than 7 The perip...

Страница 39: ...Setting SCSI IDs 2 23 Table 2 1 SCSI ID Record SCSI ID SCSI Device Channel A SCSI Device Channel B 15 14 13 12 11 10 9 8 7 LSI21003 default LSI21003 default 6 5 4 3 2 1 0...

Страница 40: ...the INTA INTB to act as a jumper for special configuration purposes This feature is not packaged with the standard LSI21003 as the default interrupt routing is sufficient for most systems In the excep...

Страница 41: ...the host adapter refer to the PCI Storage Device Management System SDMS 4 0 User s Guide for information on the BIOS software and its operation Step 6 Load the software and drivers suitable to your ap...

Страница 42: ...2 26 Installing the LSI21003...

Страница 43: ...wing of the host adapter Figure 3 1 Section 3 1 Physical Environment page 3 1 Section 3 2 Operational Environment page 3 4 Section 3 3 Subsystem and Subsystem Vendor ID page 3 12 3 1 Physical Environm...

Страница 44: ...nnel A 8 bit External SCSI connection is made to Channel A through the 50 pin high density connector J3 Connector J3 extends through the ISA EISA bracket Connector J6 connects the Busy LED It is a 4 p...

Страница 45: ...nvironment which is defined by the following parameters Temperature range 0 to 55 C dry bulb Relative humidity range 5 to 90 noncondensing Maximum dew point temperature 32 C The board is designed for...

Страница 46: ...r software An on board flash memory device is provided to allow BIOS code and open boot code support through the PCI bus and a serial EEPROM for each channel 3 2 1 The PCI Interface The PCI interface...

Страница 47: ...3 V 25 GND 46 5 V 5 C_BE3 26 AD12 47 5 V 6 AD23 27 AD10 48 INTB 7 GND 28 GND 49 INTD 8 AD21 29 KEYWAY 50 GND PRSNT1 9 AD19 30 KEYWAY 51 RESERVED 10 3 3 V 31 AD08 52 GND PRSNT2 11 AD17 32 AD07 53 KEYW...

Страница 48: ...D24 25 AD13 46 5 V 5 IDSEL 26 AD11 47 INTA 6 3 3 V 27 GND 48 INTC 7 AD22 28 AD09 49 5 V 8 AD20 29 KEYWAY 50 RESERVED 9 GND 30 KEYWAY 51 Vio 10 AD18 31 C_BE0 52 RESERVED 11 AD16 32 3 3 V 53 KEYWAY 12 3...

Страница 49: ...annel A J3 is a 50 pin high density right angle connector that protrudes through the ISA EISA bracket for external connections to Channel A Also on Channel A is connector J4 which is a 50 pin narrow r...

Страница 50: ...device by sensing SCSI standard GND on this pin 50 GND 5 GND 28 TERMPWR 51 GND 6 GND 29 TERMPWR 52 GND 7 GND 30 N C 53 GND 8 GND 31 GND 54 GND 9 GND 32 SATN 55 GND 10 GND 33 GND 56 GND 11 GND 34 SBSY...

Страница 51: ...e connection of a standard SCSI device by sensing SCSI standard GND on this pin 36 GND 3 GND 20 N C 37 GND 4 GND 21 TERMPWR 38 GND 5 GND 22 N C 39 GND 6 GND 23 GND 40 GND 7 GND 24 SATN 41 GND 8 GND 25...

Страница 52: ...1 SACK 38 GND 5 CPRSNT_C1 1 CPRSNT_C is used to sense the connection of a standard SCSI device by sensing SCSI standard GND on this pin 22 GND 39 SD2 6 N C 23 SRST 40 GND 7 N C 24 GND 41 SD3 8 N C 25...

Страница 53: ...D 28 TERMPWR 51 SD0 6 SREQ 29 TERMPWR 52 SD1 7 SI_O 30 N C 53 SD2 8 SD8 31 GND 54 SD3 9 SD9 32 SATN 55 SD4 10 SD10 33 GND 56 SD5 11 SD11 34 SBSY 57 SD6 12 SD12 35 SACK 58 SD7 13 SD13 36 SRST 59 SDP 14...

Страница 54: ...LSI21003 contains the ID numbers During system initialization the ID numbers are loaded into the Subsystem Vendor ID and Subsystem ID registers of the imbedded SCSI controller the LSI53C1010 For more...

Страница 55: ...lic name AIP Asynchronous Information Protection provides error checking for asynchronous nondata phases of the SCSI bus Asynchronous Data Transfer One of the ways data is transferred over the SCSI bu...

Страница 56: ...e reliability of data transfers CRC is used on the Double Transition DT Data In and DT Data Out phases CPU Central Processing Unit The brain of the computer that performs the actual computations The t...

Страница 57: ...he term Fast 20 Please see Ultra SCSI Fast 40 The SCSI Trade Association STA supports the use of Ultra2 SCSI over the term Fast 40 Please see Ultra2 SCSI Fast SCSI A standard for SCSI data transfers I...

Страница 58: ...ogical unit Mainboard A large circuit board that holds RAM ROM the microprocessor custom integrated circuits and other components that make a computer work It also has expansion slots for host adapter...

Страница 59: ...in 1 on a SCSI cable connector and the pin 1 position on the SCSI connector into which it is inserted External SCSI cables are always keyed to insure proper alignment but internal SCSI ribbon cables s...

Страница 60: ...and is attached to the SCSI bus by a SCSI cable This includes SCSI host adapters and SCSI peripherals SCSI ID A way to uniquely identify each SCSI device on the SCSI bus Each SCSI bus has eight availa...

Страница 61: ...SI A standard for SCSI data transfers It allows a transfer rate of up to 40 Mbytes s over an 8 bit SCSI bus and up to 80 Mbytes s over a 16 bit SCSI bus SCSI Trade Association STA supports using the t...

Страница 62: ...3 75 pc 10 25 pc 11 25 pc 38 25 pc 4 333 pc 48 583 pc 52 5 pc 34 5 pc 44 25 pc A 8 Glossary of Terms and Abbreviations...

Страница 63: ...haracteristics 1 3 PCI interface 1 2 SCSI interface 1 2 front panel LED 2 12 I inserting the host adapter 2 4 installation procedure check list 2 25 internal SCSI bus connections 2 8 J jumper settings...

Страница 64: ...IX 2 Index...

Страница 65: ...ur comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name phone number fax number and company...

Страница 66: ...number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additional information Excellent Good Av...

Страница 67: ...727 507 5000 Georgia Atlanta A E Tel 770 623 4400 B M Tel 770 980 4922 W E Tel 800 876 9953 Duluth I E Tel 678 584 0812 Hawaii A E Tel 800 851 2282 Idaho A E Tel 801 365 3800 W E Tel 801 974 9953 Ill...

Страница 68: ...781 271 9953 South Carolina A E Tel 919 872 0712 W E Tel 919 469 1502 South Dakota A E Tel 800 829 0116 W E Tel 612 853 2280 Tennessee W E Tel 256 830 1119 East West A E Tel 800 241 8182 Tel 800 633...

Страница 69: ...Tel 317 984 8608 Ligonier R A Tel 219 894 3184 Plainfield R A Tel 317 838 0360 Massachusetts Burlington SGY Tel 781 238 0870 Michigan Byron Center R A Tel 616 554 1460 Good Rich R A Tel 810 636 6060...

Страница 70: ...ton Mint Technology 77 South Bedford Street Burlington MA 01803 Tel 781 685 3800 Fax 781 685 3801 Minnesota Minneapolis 8300 Norman Center Drive Suite 730 Minneapolis MN 55437 Tel 612 921 8300 Fax 612...

Страница 71: ...Singapore Singapore LSI Logic Pte Ltd 7 Temasek Boulevard 28 02 Suntec Tower One Singapore 038987 Tel 65 334 9061 Fax 65 334 4749 Sweden Stockholm LSI Logic AB Finlandsgatan 14 164 74 Kista Tel 46 8...

Страница 72: ...ei Time24 Bldg 35 Tansu cho Shinjuku ku Tokyo 162 0833 Tel 81 3 3260 1411 Fax 81 3 3260 7100 Technical Center Tel 81 471 43 8200 Marubeni Solutions 1 26 20 Higashi Shibuya ku Tokyo 150 0001 Tel 81 3 5...

Отзывы: