Detailed Installation Procedure

1-5

Rev. 2.0

Copyright © 2002 by LSI Logic Corporation. All rights reserved.

Figure 1.1

Hardware Connections for the LSI Logic Host Adapter

Step 7.

Carefully insert edge connector J1 (see

Figure 1.1

of the host

adapter into the PCI slot.

Make sure the edge connector is properly aligned before
pressing the board into place as shown in

Figure 1.2

The

bracket around connector J2 should fit where you removed the
blank panel.

SFF Optical

Connector

Fibre Channel

Link Activity/

Link Fault LED

PCI Bus Edge Connector J1

LSI Logic Host Adapter

Содержание ITI7004G2-

Страница 1: ...DB15 000182 01 2 Gbit s Fibre Channel to PCI Host Adapters USER S GUIDE M a r c h 2 0 0 2 Version 2 0...

Страница 2: ...etween the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...

Страница 3: ...ontained in the International Electrotechnical Commission IEC standard 825 1 1993 Class 1 laser products are not considered to be hazardous based upon current medical knowledge This class includes all...

Страница 4: ...y responsibility or liability arising out of the application or use of any product described herein except as expressly agreed to in writing by LSI Logic nor does the purchase or use of a product from...

Страница 5: ...ion This document has the following chapters and appendix Chapter 1 Installing the 2 Gbit s Host Adapters describes the installation procedures for the 2 Gbit s host adapters Chapter 2 2 Gbit s Host A...

Страница 6: ...usion MPT Device Management User s Guide September 2001 LSI Order DB15 000186 00 Revision Record Revision Date Remarks 1 0 06 01 First printing 2 0 03 02 Final printing Changes throughout including ad...

Страница 7: ...Adapter Characteristics 2 1 General Description 2 1 2 1 1 Hardware and Software Support 2 2 2 2 Features 2 3 2 2 1 PCI Interface 2 3 2 2 2 FC Interface 2 4 2 3 Physical Environment 2 4 2 3 1 Electric...

Страница 8: ...2 6 13 LSI44929H Host Adapter Configuration 2 20 2 6 14 LSI44929H Connectors 2 21 2 6 15 LSI44929LH Host Adapter Configuration 2 22 2 6 16 LSI44929LH Connectors 2 23 2 6 17 ITI7004G2 LC Host Adapter...

Страница 9: ...Installation 4 9 4 8 4 Adapter Specific Settings 4 10 4 8 5 Interrupt Coalescing 4 12 4 8 6 Set Fibre Channel Link Speed 4 13 4 8 7 Persistent Device Naming 4 14 4 8 8 Manual Selection of Fibre Chann...

Страница 10: ...04G2 LC Host Adapter Configuration 2 24 2 18 ITI7004G2 LC Connectors and Indicator LEDs 2 25 Tables 1 1 LSI Logic 2 Gbit s Controllers and Associated Host Adapters 1 1 2 1 LSI Logic 2 Gbit s FC Host A...

Страница 11: ...T Windows 2000 Drivers page 1 2 Section 1 3 Quick Host Adapter Installation Procedure page 1 2 Section 1 4 Detailed Installation Procedure page 1 3 1 1 General Description LSI Logic provides high perf...

Страница 12: ...ectory through the MINIPORT subdirectory I386 WINNT MINIPORT to the root directory of a clean diskette You will use the driver diskette during installation process Contact the LSI Logic technical supp...

Страница 13: ...structions for installing the host adapter If you are experienced in these tasks you may prefer to use Section 1 3 Quick Host Adapter Installation Procedure 1 4 1 Before You Start Before starting look...

Страница 14: ...your body can damage electronic components Handle plug in boards by the edge do not touch board components or gold connector contacts The use of a static ground strap is recommended Step 5 Locate the...

Страница 15: ...ly insert edge connector J1 see Figure 1 1 of the host adapter into the PCI slot Make sure the edge connector is properly aligned before pressing the board into place as shown in Figure 1 2 The bracke...

Страница 16: ...Corporation All rights reserved Figure 1 2 Inserting the Host Adapter Step 8 Secure the board with the bracket screw see Figure 1 2 before making the external FC link connection Step 9 Reconnect all...

Страница 17: ...re Channel to PCI host adapter family uses state of the art 2 Gbit s Fibre Channel technology to provide the highest possible performance and most flexible storage configuration available Adapters are...

Страница 18: ...tem driver that supports Fibre Channel devices and other bus architectures For more information regarding software support for the 2 Gbit s Fibre Channel to PCI host adapter family see the Fusion MPT...

Страница 19: ...e channel and the LSIFC929 dual channel contain the PCI functionality for all the LSI Logic 2 Gbit s Fibre Channel to PCI host adapters The PCI interface includes these features Full 64 bit DMA bus ma...

Страница 20: ...PCI host adapters The LSIFC919 LSIFC929 generate signal timing and link protocol in compliance with FC standards The FC interface includes these features 2 Gbit s serial link LSIFC919 LSIFC929 functi...

Страница 21: ...dry bulb Relative humidity range 5 to 90 noncondensing Maximum dew point temperature 32 C The following parameters define the storage and transit environment for these host adapters Storage Temperatur...

Страница 22: ...I computer systems The LSI Logic supplied FC BIOS and firmware operate the boards An on board flash memory device and a serial EEPROM are provided to allow BIOS code and open boot code support through...

Страница 23: ...dapters 2 5 IEEE Unique Address Each LSI Logic 2 Gbit s host adapter channel is provided with a unique World Wide Name specified by IEEE The last six hexadecimal characters of this address appear on a...

Страница 24: ...ice providing one Fusion MPT channel The LSI40919O is a PCI low profile short card with standard height bracket the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC connec...

Страница 25: ...gured as shown in Figure 2 2 One LC connector is used to connect the adapter channel to the Fibre Channel subsystem The indicator LED is used to indicate link status activity and link fault Figure 2 2...

Страница 26: ...O uses one LSIFC919 device providing one Fusion MPT channel The LSI40919LO is a PCI low profile short card the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC connection...

Страница 27: ...gured as shown in Figure 2 4 One LC connector is used to connect the adapter channel to the Fibre Channel subsystem The indicator LED is used to indicate link status activity and link fault Figure 2 4...

Страница 28: ...one LSIFC919 device providing one Fusion MPT channel The LSI40919H is a PCI low profile short card with standard height bracket the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The e...

Страница 29: ...Logic Corporation All rights reserved 2 6 6 LSI40919H Connector The LSI40919H I O bracket is configured as shown in Figure 2 6 One HSSDC connector is used to connect the adapter channel to the Fibre...

Страница 30: ...SI40919LH uses one LSIFC919 device providing one Fusion MPT channel The LSI40919LH is a PCI low profile short card the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC con...

Страница 31: ...Logic Corporation All rights reserved 2 6 8 LSI40919LH Connector The LSI40919LH I O bracket is configured as shown in Figure 2 8 One HSSDC connector is used to connect the adapter channel to the Fibre...

Страница 32: ...viding two Fusion MPT channels The LSI44929O is a PCI low profile short card with standard height bracket the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC connections...

Страница 33: ...2 10 Two LC connectors are used to connect the adapter channel to the Fibre Channel subsystem The indicator LEDs are used to indicate link status activity and link fault for each channel Figure 2 10...

Страница 34: ...929 device providing two Fusion MPT channels The LSI44929LO is a PCI low profile short card the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC connections are made throu...

Страница 35: ...2 12 Two LC connectors are used to connect the adapter channel to the Fibre Channel subsystem The indicator LEDs are used to indicate link status activity and link fault for each channel Figure 2 12...

Страница 36: ...SIFC929 device providing two Fusion MPT channels The LSI44929H is a PCI low profile short card with standard height bracket the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The extern...

Страница 37: ...orporation All rights reserved 2 6 14 LSI44929H Connectors The LSI44929H I O bracket is configured as shown in Figure 2 14 Two HSSDC connectors are used to connect the adapter channel to the Fibre Cha...

Страница 38: ...9LH uses one LSIFC929 device providing two Fusion MPT channels The LSI44929LH is a PCI low profile short card the dimensions are 6 6 x 2 53 inches J1 is the PCI edge connector The external FC connecti...

Страница 39: ...poration All rights reserved 2 6 16 LSI44929LH Connectors The LSI44929LH I O bracket is configured as shown in Figure 2 16 Two HSSDC connectors are used to connect the adapter channel to the Fibre Cha...

Страница 40: ...hannels The ITI7004G2 LC is a PCI short card the dimensions are 6 875 x 4 2 inches J1 is the PCI edge connector The external FC connections are made through four 2 Gbit s SFF optical modules The compo...

Страница 41: ...are used to connect the adapter channel to the Fibre Channel subsystem The indicator LEDs are used to indicate link status activity and link fault for each channel Figure 2 18 ITI7004G2 LC Connectors...

Страница 42: ...2 26 2 Gbit s Host Adapter Characteristics Ver 2 0 Copyright 2002 by LSI Logic Corporation All rights reserved...

Страница 43: ...ing the Firmware page 3 4 Section 3 5 Troubleshooting page 3 7 3 1 Introduction The LSI Logic Fibre Channel chips and host adapters contain firmware that presents a multi protocol service layer based...

Страница 44: ...support FC Tape FC AL2 Class 3 confirmed delivery support LSI Logic Fusion MPT common software interface Initiator Target and FC LAN capability 3 2 2 Description The LSIFC929 controller operates in an...

Страница 45: ...IFC919 Fibre Channel chip or host adapter Locate the FCUTIL EXE program and FC929 ROM code on your distribution media as well as the DOS4GW EXE file Copy these files to a blank formatted diskette Labe...

Страница 46: ...ion the LSI Logic host adapters may be configured to either the 2 Gbit s or 1 Gbit s speed specifically Note that the LSI44929 has two FC ports the ITI7004G2 LC has four so the link speed must be conf...

Страница 47: ...s command from DOS A fcutil The FCUTIL program identifies all LSI Logic host adapters in the system and allows you to select which adapter to update Step 2 The FCUTIL program displays a menu of option...

Страница 48: ...ized for very high performance servers and peripherals The user can decrease this value to improve system performance if the system contains lower performance servers and or peripherals The Coalescing...

Страница 49: ...version number of the Firmware The UNIX compatible WHAT EXE program for DOS included on your distribution media can be used to identify the ROM files on the diskette s Examples what what nt Many types...

Страница 50: ...3 8 Firmware Installation Procedure Ver 2 0 Copyright 2002 by LSI Logic Corporation All rights reserved...

Страница 51: ...the Intel BIOS Configuration Utility page 4 6 Section 4 7 Troubleshooting page 4 6 Section 4 8 Open Boot BIOS page 4 7 4 1 Introduction A BIOS is the ROM code that is loaded by the system to facilita...

Страница 52: ...Intel BIOS maps any Intel drives it finds after the drive s already installed Otherwise the Intel BIOS installs drives starting with the system boot drive In this case the system boots from a drive c...

Страница 53: ...by the Configuration Utility can be controlled by the BIOS Devices such as tape drives and scanners require that a device driver specific to that periph eral be loaded The BIOS Configuration Utility d...

Страница 54: ...ter s device settings To display this menu select a device under the Adapter field on the Main menu and press Enter 4 5 2 Persistent IDs Menu The Persistent ID screen is used simply to review the auto...

Страница 55: ...to the first and last columns 4 5 4 Boot Adapter List Menu The Boot Adapter List menu specifies the order in which adapters boot when more than one LSI Logic host adapter is in a system Up to four ada...

Страница 56: ...the Main menu use these exit options Important If you reboot the system without properly exiting from this utility some changes may not take effect 4 7 Troubleshooting The LSI Logic Intel BIOS Configu...

Страница 57: ...trl C to start LSI Logic Configuration Utility appears when fewer than four adapters are in the boot order and adapters exist in the system which are not in the boot order This message is for informat...

Страница 58: ...er this command ok probe scsi all pci 8 600000 SUNW qlc 4 LiD HA LUN Port WWN Disk description 1 1 0 2100002037e4d65b SEAGATE ST318304FSUN18G 0726 pci 8 700000 IntraServer Ultra160 scsi 3 1 pci 8 7000...

Страница 59: ...match that of the bus 1G 2G or Auto If you do not see disks the following additional debug information may help to identify the problem 4 8 3 Verifying Correct Installation Use this procedure to verif...

Страница 60: ...system and configuration Use the corresponding entries on your system not the ones given here If these devices are not listed check to assure that the adapter is correctly installed and re seat the a...

Страница 61: ...0190000 00000000 00010000 82001030 00000000 02000000 00000000 00100000 compatible 70 63 69 31 33 65 39 2c 36 32 31 00 70 63 69 31 model LSI 929 reg 00001000 00000000 00000000 00000000 00000000 0100101...

Страница 62: ...WN 210000203710565a Port ID 17 Target 2 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037105212 Port ID 1 Target 3 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037103da8 Port ID 26 Target 4 Unit 0 Di...

Страница 63: ...econds Interrupt coalescing depth is 9 9 decimal ok set interrupt coalescing command with no arguments prints help usage is timeout depth set interrupt coalescing ok 100 8 set interrupt coalescing Int...

Страница 64: ...ed selected is autobaud Current link speed is 1 Gbaud Note The system must be power cycled before the changes take effect It is not sufficient to execute the reset all command 4 8 7 Persistent Device...

Страница 65: ...PortID a3 ok set persistent command with no arguments prints help usage is current target id persistent target id set persistent ok 0 0 set persistent ok show persistent Entry 1 WWN 200000203710c4e8...

Страница 66: ...ide 3 disk e pci 1f 0 pci 1 1 ebus 1 fdthree 14 3203f0 q NO SELECTION Enter Selection q to quit a pci 1f 0 pci 1 IntraServer fc 2 disk has been selected Type Y Control Y to insert it in the command l...

Страница 67: ...ed is N_Port Topology has been set Change will take effect after system power cycle ok a set topology Topology selected is auto Topology has been set Change will take effect after system power cycle N...

Страница 68: ...4 18 BIOS Features Ver 2 0 Copyright 2002 by LSI Logic Corporation All rights reserved...

Страница 69: ...information a computer uses The value of a bit 0 or 1 represents a two way choice such as on or off true or false and so on Broadcast Sending a transmission to all N_Ports on a fabric Bus A collectio...

Страница 70: ...device directly to RAM without using the CPU s resources DMA Bus Master A feature that allows a peripheral to control the flow of data to and from system memory by blocks as opposed to PIO Programmed...

Страница 71: ...use of optical fiber cable to transmit data at 100 Mbits s Fibre Channel Fibre Channel is the general name of an integrated set of standards being developed by the Americal National Standards Institut...

Страница 72: ...eceive data up to 16 bits at a time Kbyte Kilobyte A measure of computer storage equal to 1024 bytes LCT Logical Configuration Table Link_Control_ Facility A termination card that handles the logical...

Страница 73: ...s Originator A FC term referring to the initiating device Parity Checking A way to verify the accuracy of data transmitted over the SCSI bus One bit in the transfer is used to make the sum of all the...

Страница 74: ...ansfer data pointer so that a single host adapter transfer can access many segments of memory This minimizes interrupts and transfer overhead SCB SCSI Command Block SCSI Small Computer System Interfac...

Страница 75: ...and computer system TID Target ID Topology The logical and or physical arrangement of stations on a network ULP Upper Layer Protocol VCCI Voluntary Control Council for Interference Virtual Memory Spa...

Страница 76: ...A 8 Glossary of Terms and Abbreviations Ver 2 0 Copyright 2002 by LSI Logic Corporation All rights reserved...

Страница 77: ...e copy the following page add your comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name phon...

Страница 78: ...please specify the error and page number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additio...

Страница 79: ......

Страница 80: ...You can find a current list of our U S distributors international distributors and sales offices and design resource centers on our web site at http www lsilogic com contacts na_salesoffices html...

Отзывы: