3-6
Firmware Installation Procedure
Ver. 2.0
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
The Coalescing Timeout value determines how long the host
adapter waits before generating an interrupt, when less than
Coalescing Depth I/O requests are present. By default, the host
adapter is pre-programmed with a value of 0x500
µ
sec. This
default value is optimized for very high performance servers
and peripherals. The user can decrease this value to improve
system performance, if the system contains lower performance
servers and/or peripherals.
The Coalescing Depth value determines how many requests
are queued before generating an interrupt. By default, the host
adapter is pre-programmed with a value of 0x9. This default
value is optimized for very high performance servers and
peripherals. The user can decrease this value to improve
system performance, if the system contains lower performance
servers and/or peripherals.