UNITOUR Power System
User Manual
Page 15
1.7.3
Power Status Indicators
The
“Power Status Indicators” of the 48 channel model are located above the PowerLock
connectors. The FAULT indicator is red and the Earth, Neutral, L1, L2, L3 indicators are green.
If the system does not have a good Earth or Neutral connection or if there is a L (Phase) /
Neutral swap or a L (Phase) / Earth swap, then the
red “FAULT” LED comes on and a warning
appears on the touch screen. The system cannot be operated until the problem is resolved
and the
red “FAULT” LED lights is off. A full power cycle must then be performed (all power
removed and restored) to remove the warning message on the screen.
UNITOUR will operate with only 1 or 2 phases connected provided that it has both a Neutral
and an Earth connection.
A duplicate set of Power Status indicators are located on the front panel, adjacent to the
master switch.
1.7.4
Controlled Power Output Connectors
The UNITOUR Choice of output connectors,
•
Dual (parallel wired) Socapex 19-pin with 6 circuits per connector.
•
Dual (parallel wired) Wieland 16-pole with 6 circuits per connector.
•
Dual (parallel wired) Wieland 10-pole with 6 circuits per connector.
See section 6 for more details of the connectors.
1.7.5
Auxiliary Power Output Connectors
One 3 phase and three single phase outlets are located on the rear panel, protected by
individual RCD/MCBs located on the front panel.
Australian models are fitted with one 32A 3-
phase outlet plus 3 x
Australian
20A 3-pin
single phase outlets protected by 16A
RCBO
’s
.
European models are fitted with one CEE
32A 3-phase outlet plus 3 x CEE 16A single
phase outlets protected by 16A RCBO
’s.