Menu System
Redback Dimmer
Operator Manual V1.1
4 M e n u S y s t e m
4.1 Menu Structure
Redback has a two level menu system.
The Basic menu provides access to those
settings needed for general day-to-day use of
the Redback in production.
The Advanced menu gives access to
configuration and operations options required for
more complex operating environments, dimmer
configuration and dimmer diagnostics.
4.2 Control Pad
All menu operations on Redback are accessed
via the five-button control pad and the Menu
scroll keys.
The
Left
and
Right
arrow keys are used to
step between the parameters being set in the
selected function.
The
Up
and
Down
arrow keys are generally
used to increase or decrease the values for the
selected parameter.
The
3
Flip
key is generally used to switch
between text and graphical modes on the LED
display.
The red
Menu Up
S
and
Menu Down
T
keys
scroll between menu functions.
4.3 Menu LEDs
The menu LEDs
W
indicate the currently active
menu function.
A double flashing menu LED indicates that an
option is active and overriding basic DMX
control.
The Advanced Menu [ADV] LED double-flashes
to indicate that Advanced functions are
overriding basic dimmer settings.
4.4 Status LEDs
4.4.1 DMX DATA
The DATA LED illuminates to indicate the
presence of DMX512 data on the DMX INPUT
connector. If the data signal is lost, the indicator
double-flashes to indicate data failure. All
dimmers will hold their current levels until data is
restored or the Redback is powered down or re-
set.
4.4.2 DMX ERR
The DMX Error LED flashes to indicate errors in
the DMX512 data arriving at the DMX INPUT
connector.
The problems that cause error indication
include:
•
a noisy DMX512 signal due to poor or
damaged cables or connections,
particularly if the shielding is not
continuous or one of the signal pair is
broken.
•
damaged or incomplete data packets
from a faulty DMX512 transmitter on a
control console or a data splitter.
4.4.3 ~1 ~2 ~3 (Mains power)
The three power indicator LEDs illuminate to
indicate the presence of the mains power supply
to the Redback.
Three Phase Supply
When configured for three phase operation, the
~1 ~2 ~3 LEDs indicate the availability of the
corresponding phase of mains supply All three
supply phases must be present for full operation
of all dimmers.
Single Phase Supply
When configured for single phase operation,
input supply cabling is bridged and all three
power LEDs illuminate if the mains supply is
available.
4.5 LED Screen
The LED panel has both text and graphical
display modes.
4.5.1 Text Mode
A L L C H
Menu selections and settings are generally
displayed as text.
4.5.2 Graphical Mode
Dimmer levels are displayed in graphical mode.
This example shows:
Dimmer
1 2 3 4 5 6 7 8 9
10 11 12
Level
Fl 25 50 75 80 33 66 99 95 90 85 5
The height of the column indicates the level of
the dimmer. The brightness of the topmost LED
provides a finer level of indication.
Symbol
Level
~5%
~10% ~15% ~20%
The two additional LEDs on either side of the
level for dimmer 12 indicate that dimmer 12 is
the dimmer currently selected for adjustment.
Page 6
LSC Lighting Systems (Aust) Pty. Ltd
Содержание Redback 12 Channel
Страница 4: ......