Chapter3. Status Diagnostic and LED Indication
11
Blinking every
second
(contrary to
CPU LED)
CONFIG
ERROR
Master’s
configuration
Data is
different from
Profibus-DP
module’s
configuration.
Check the
configuration
data set on
Master and
the internal
configuration
data at the
inverter.
ON-
LINE
OFF
Off-Line
Master doesn’t
work for
communication
in the network.
Start the
communication
from Master.
The
connection of
connector has
a problem.
Check the
connection
between the
pin number of
connector and
the termination
resistor.
There is no
master in the
network.
It can be
possible there
is no
designated
master or
master has a
problem.
Wrong setting
of station ID
Check if the
station ID set
in the
designated
Profibus
communicatio