6. Output terminal connection
The LS 48.6V / 166F Ultracapacitor Modules are designed to connect directly to a
ring or a bus bar. The positive and negative terminals have each hole for the screw.
The positive terminal threaded size is M8 and negative terminal is M10. Wave
washers are required to ensure long term, reliable connections.
When tightening the terminal bolt, a torque of 20 N-m for the M8 bolt should be
used.(30N-m for the M10 bolt) Because the modules have a very low ESR, total ESR
will be affected by a ring lug, bus bar or torque. Therefore, it needs more attention to
assemble the modules. And appropriate protection and sealing should be used on
both module terminals to avoid shock hazards and corrosion.