Description
Protection
function
Trips
•
Over voltage
•
Low voltage
•
Over current
•
Earth current detection
•
Inverter overheat
•
Motor overheat
•
Output imaging
•
Overload protection
•
Network
communication error
•
Lost command
•
Hardware failure
•
Cooling fan failure
•
Pre-PID failure
•
No motor trip
•
External trip
•
Other safety functions
Alarms
•
Stall prevention
•
Overload
•
Light load
•
Encoder error
•
Fan failure
•
Keypad command loss
•
Speed command loss
Instantaneous
blackout
Less than 15 ms (CT) [Less than 8 ms (VT)]: Continue
operation (must be within the rated input voltage and rated
output range).
Over 15 ms (CT) [Over 8 ms (VT)]: Automatically restart
2.6.4
Structure and Operating Environment Control
Items
Description
Structure/
operating
environment
Cooling type
Forced cooling: 0.75
–
15 kW (200/400 V class),
22 kW (400 V class)
Inhalation cooling: 22
–
75 kW (200 V class),
30
–
375 kW (400 V class)
Protection
structure
- 0.75
–
22 kW (200V), 0.75
–
75 kW (400 V): Open type IP 21
(default), UL enclosed type 1 (optional)*
- 30
–
75 kW (200 V), 90
–
375 kW (400 V): Open type IP 00
- 0.75
–
22 kW, frame types 2, 4 and others.: Enclosed IP54
type, UL enclosed type 12
Ambient
temperature
•
CT load (heavy duty): -10
–
50
℃
•
VT load (normal duty): -10
–
40
℃
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...