Table of Functions
149
4.10
Protection Function group (PAR
→
Pr)
In the following table, the data shaded in grey will be displayed when a related code has
been selected.
SL
: Sensorless vector control (dr.09) , I – IM Sensorless, P – PM Sensorless
*
O/X
: Write-enabled during operation,
7/L/A
: Keypad/LCD keypad/Common
Code
Comm.
Address
Name
LCD Display Setting Range
Initial
Value
Property* V/F SL
00
-
Jump Code
Jump Code 1-99
40
O/A
O I/P
04 0h1B04
Load level
setting
Load Duty
0
62
Normal
Duty
1:Heavy
Duty
X/A
O I/P
1
Heavy
Duty
05 0h1B05
Input/output
open-phase
protection
Phase Loss
Chk
bit 00-11
00
63
X/A
O I/P
01
Output
open
phase
10
Input open
phase
06 0h1B06
Input voltage
range during
open-phase
IPO V Band 1-100(V)
15
X/A
O I/P
07 0h1B07
Deceleration
time at fault
trip
Trip Dec
Time
0.0-600.0(s)
3.0
O/A
O I/P
08 0h1B08
Selection of
startup on trip
reset
RST Restart
0 No
0:No
O/A
O I/P
1 Yes
09 0h1B09
Number of
automatic
restarts
Retry
Number
0-10
0
O/A
O I/P
62
IP66 models do not support normal duty setting.
63
The initial value 0000 will be displayed on the keypad as
.
Содержание LSLV-S100 Series
Страница 1: ......
Страница 11: ...Preparing the Installation 2 ...
Страница 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Страница 16: ...Preparing the Installation 7 Front cover removed ...
Страница 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Страница 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Страница 67: ...Installing the Inverter 58 ...
Страница 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Страница 71: ...Learning to Perform Basic Operations 62 3 1 3 2 30 75kW Models Monitor mode display Parameter settings display ...
Страница 193: ...Table of Functions 184 ...
Страница 205: ...196 Troubleshooting ...
Страница 222: ...Technical Specification 213 7 3 External Dimensions 0 4 22kW Models 0 4 kW Single Phase 0 4 0 8 kW 3 Phase ...
Страница 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Страница 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Страница 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Страница 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Страница 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Страница 259: ...250 ...
Страница 261: ...252 ...
Страница 263: ...254 ...