Detailed operation by function groups
178
Operation by battery power (Battery Run)
When the inverter is used to operate elevators, battery power may be used as
the emergency power source if power failure occurs during elevator operation.
For more details, refer to
6.5.10 Setting the operation speed and input voltage
on page
6.3.2.2 Reversing the multifunction terminal input (DIO_08)
Multifunction input terminals are “Form A” contacts by default. The DIO_08
parameter is used to change the contact type to “Form B” by setting the binary
code for each terminal to “1.”
When the contact type for a terminal is changed, the setting is maintained until it
is modified again by the user.
Note that setting the external trip B terminal to a “Form B” contact makes it work
as the external trip A terminal.
On the keypad display, the binary digits as they appear from left to right
represent the contact type for the FX, RX, BX, RST, P1, P2, P3, P4, P5, P6, and
P7 terminals.
6.3.2.3 Setting the LPF (Low pass filter) time constant for
terminal input (DIO_09)
The low pass filter is used to reduce the level of electronic signal interference.
The setting at DIO_09 configures the responsiveness of the input terminals (FX,
RX, BX, RST, and P1–P7). Increasing the time constant decreases the
responsiveness of the input terminal and decreasing it increases the
responsiveness. The approximate response time of a terminal can be calculated
by: Setting value × 2.5 ms
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...