background image

LRP electronic GmbH

Hanfwiesenstraße 15
73614 Schorndorf
Deutschland

Dear customer,

Thank you for your trust in this LRP product. By purchasing an LRP iX8 V2 brushless speed-control, 
you have chosen one of the most advanced and successful speed-controls of today. The new iX8 V2 
has been optimized with the following newly developed high tech features:

• Initial drive mode 

• USB Software Updatability

• 2S to 6S operation 

• Fully adjustable

• 6.0V / 6.0A Switching BEC 

• AutoCell System 2

• Internal-Temp-Check System 3 

• Multi-Protection System 3

Please read the following instructions carefully before you start using your speed control. This user 
guide contains important notes for the safety, the use and the maintenance of this product. Thus 
protecting yourself and avoid damages of the product.
Proceed according to the user guide in order to understand your speed control better. Please take 
your time as you will have more joy with your product if you know it exactly.
This user manual shall be kept in a safe place. If another customer is using this product, this manual 
has to be handed out together with it.

1. Specifications

Pure Brushless Competition

yes

Reverse Motor Rotation Mode

yes

Forward/Brake

yes

BR2-Brake

yes

Forward/Brake/Reverse

yes

Multi-Protection-System 3

yes

Size

55x40mm

Internal-Temp-Check System 3

yes

Height

25mm

Blue LED

yes

Weight (excl. wires)

62.0g

Power Wires

3.3mm² + G4

Voltage Input

7.2-22.2V (2S-6S)

USB Software Updatability

yes

Typ. Voltage Drop* @20A

0.007V / phase

Plugged Fan

yes

Rated Current*

600A / phase

Adjustable Modes

4

Switching BEC

6.0V / 6.0A

* Transistors rating at 25°C junction temperature. Specifications subject to change without no-
tice.

2. Connections & Explanations

Receiver & Switch Connecting 

Wires: 

The iX8 V2 is equipped with 

pluggable LRP Multicon receiver 
wire + pluggable switch wire. As 
supplied, it will easily fit in all ordi-
nary receivers. Make sure you con-
nect the receiver wire with correct 
polarity and use channel 2.

Sensor Connector: 

The bi-directio-

nal multipole sensor wire connects 
the speed-control and the motor. 
Always use the sensor wire and do 
not alter or modify this cable! There 
are replaceable/optional hall sensor 
wires available.
Through this sensor connector, the 
speedo can also be updated with the 
latest software updates using the optional „USB Bridge #81801“. Please refer to chapter „USB Soft-
ware Updatability“ for details

Power Wires: 

For maximum convenience and performance, the flexible silicone power wires are a 

plug-in design using high-power 4.0mm power sockets & connectors. There are replacement power 
wires available, please refer to complete line-up at www.LRP.cc.

Note: 

In high temperature and high load conditions we recommend to cut the 4mm plugs and solder 

motor cables directly to the motor. You should always check all connections that the connector plugs 
are tightly placed in power sockets. This protects your speedo from shutdowns and defects!

Heatsink: 

To achieve best perfomance even under extreme conditions, the heatsink is an integral part 

of the design and directly connected to the FETs. This ensures the best possible heat transfer away 
from the speed-control.

Plugged Cooling Fan: 

The iX8 V2 comes with a high-performance low-profile (30x30x6mm) fan, 

protection cover and mounting screws. The fan can be mounted on top of the heatsink and should 
be used for tough applications in hot conditions. It gets plugged into the 3-pin connector on the front.

3. Installation Guide

•  Position the speed-control where it is protected in the event of a crash and gives you easy access 

to the connectors and buttons.

•  Mount the speedo using the supplied thick/black doubled-sided tape.
•  Make sure there is enough clearance between the speed-control, power-wires, antenna and 

receiver. Avoid any direct contact between power components, the receiver or the antenna as this 
can cause interference. If interference occurs, position the components at a different place in the 
model.

•  The aerial should be run vertically up and away from the receiver. Avoid contact with any parts 

made of carbon fibre or metal. If the aerial is too long, don’t coil up the excess length. See also the 
instructions supplied with your radio control system.

The iX8 V2 comes supplied with flexible 3.3mm² silicone power-wires and attached 4.0mm bullet 
connectors. Be very careful with the correct wire sequence/colors since an incorrect connection may 
damage the speed-control! Avoid creating solder bridges on the solder-tabs and isolate all connec-
tions carefully.
  • Connect the speed-control to the receiver (position: Channel 2)
  • Blue power-wire 

 Speedo MOT.A to motor „A“

  • Yellow power-wire 

 Speedo MOT.B to motor „B“

  • Orange power-wire 

 Speedo MOT.C to motor „C“

  • Connect the hall sensor cable to the speed-control and the motor.
  • Doublecheck all connections before connecting the speed-control to a battery.
      

CAUTION:

 If battery is connected with reversed polarity it will destroy your speed-control!

  • Red power-wire 

 Speedo BAT+ to battery „Plus“

  • Black power-wire 

 Speedo BAT- to battery „Minus“

 Your speed-control is now ready to be set-up.

4. Calibrate Speed-Control to Radio

In setup mode the speed-control stores every step (e.g. learning your radios neutral and endpoints) 
by pressing the SET button. All the settings will be stored in the memory even if it will be discon-
nected from the battery.

•  This completes the setup procedure and your iX8 V2 is ready to use.
•  If you make a mistake during the setup procedure, don‘t worry: Disconnect the battery for about 

10sec and start again from the first step.

•  At the start of each run switch on the transmitter first, then switch on the car.
•  At the end of each run switch off the car, and then switch off the transmitter.
•  For storage of the car, disconnect the drive battery at any time!

Check the LEDs when moving the throttle on your radio to doublecheck everything is setup correctly.

5. Multi Protection System 3

New and improved protection system „MPS3“ which also tells you the cause of the shutdown 
with a special LED flashing sequence. You can indicate that a shutdown occured when blue SET 
LED flashes very fast and the „error code“ (= cause for shutdown) is indicated by the MODE LEDs 
as explained in the table below.

Error Code LED flashing sequences:

Error

Code

Set

LED

Mode

LEDs

Reason

Possible Cause

#1

Blue 

(fast 

flashing)

Yellow

Speed-Control Thermal Shutdown 1. too strong motor or too high battery voltage for application

2. insufficient cooling of speed-control or motor.

3. too high gear ratio?

#2

Red

Motor Thermal Shutdown

#3

Yellow/Red

(alternate) Battery Low Voltage Cut-Off

1. battery empty?

2. battery empty or weak?

3. motor too strong for battery discharge capability?

4. poor connection (bad connector, bad soldering joint)?

#4

Yellow/Red

(same time) Motor Failure

1. sensor wire missing or defective?

2. drivetrain stuck?

3. motor defective (locked rotor, damaged sensor)?

Internal-Temp-Check System 3:

 Allows you to read-out the maximum internal temperature that 

the speedo and motor have reached during the run. You can conveniently read-out the tempera-
ture back in the pits since it remains stored until you turn it on the next time regularly (which will 
reset the memory). This feature allows you to accurately check if all is running well or if you‘re 
close to shutdown already.

How to read-out the temperature:

 

Switch at „OFF“ position.

  Keep MODE button pressed while you turn switch to „ON“ (then release button).

  At first speed-control temperature will be indicated.

 

SET LED will start to flash blue (MODE LEDs are off) ....

  Count the number of flashes.The higher the number, the hotter the speedo ran (shutdown 

occurs at 10 flashes).

  To change to motor temperature read-out, press MODE button one more time.

  SET LED will start to flash blue (MODE LEDs are off) again, for motor the LEDs on time will be 

shorter.

 Count the number of flashes.The higher the number, the hotter the motor ran (shutdown 

occurs at 10 flashes).

  Every flash below 10 equals to 5°C temperature decrease.

Temperature chart (speed-control and motor temperature):

 
 

CAUTION:

 motor temperature read-out only works if your motor has a built-in NTC temperature 

sensor!

#80881

IX8 VERSION 2

USER MANUAL

RA00317 Version 19.03.2015 © LRP electronic GmbH 2015

The crossed-out wheeled bin means that within the European Union the product must be taken to separate 

collection at product end-of life. Do not dispose these products as unsorted municipal waste.

LATEST V2.6 TEAM FIRMWARE
2S TO 6S LIPO CAPABILITY
6.0V / 6.0A SWITCHING BEC
USB SOFTWARE UPDATABILITY

Rec

ei

ve

rw

ire

M

O

DE

 b

ut

ton

/L

ED

SE

T b

ut

ton

/L

ED

O

n/

O

ff - S

w

itc

h

Motor „C“

Orange Wire

Motor „B“

Yellow Wire

Motor „A“

Blue Wire

Red Wire

Battery - 

Black Wire

Se

ns

or

 

Co

nn

ec

to

r

Fa

n

Co

nn

ec

to

r

• Connect the speed-control to the battery and switch the unit on.
• Hold the SET button pressed for at least 3sec.

 

 You entered setup mode and the SET LED flashes blue (it will flash until the setup is completed).

• Leave transmitter in neutral position and press the SET button once.

 

 Neutral setting is stored , MODE LED flashes yellow and the motor beeps.

• Hold full throttle on transmitter and press the SET button once.

 

 Full-throttle setting is stored, MODE LED flashes red.

• Hold full brake on transmitter and press the SET button once.

 

 Brake setting is stored, LEDs glow red (MODE) and blue (SET).

Function

Status

Mode LED

Set LED

Neutral

--

off

blue

Forward

partial

yellow

off

full

blue

Brake/Reverse

partial

red

off

full

blue

#1

#2

#3

#4

#5

#6

#7

#8

#9

#10

> -45°C

> -81°F

-40°C

-72°F

-35°C

-63°F

-30°C

-54°F

-25°C

-45°F

-20°C

-36°F

-15°C

-27°F

-10°C

-18°F

-5°C

-9°F

Shutdown

Throttle Travel

High ATV, EPA

100%

Brake Travel

Low ATV, EPA, ATL

100%

Throttle Exponential

EXP, EXPO

start with 0

Neutral Trim

SUB Trim

centre

Servo Reverse

Throttle Reverse

any setting, don‘t change after set-up procedure!

TRANSMITTER SETTINGS: 

Setup the following basic functions on your transmitter (if available):

If your transmitter doesn‘t offer any of above functions, it‘s already in „basic setup“ mode.

• Ensure that the speed-control is not connected to the drive battery and is switched off.
• Remove motor pinion or ensure that the wheels of the model are free to rotate.
• Switch the transmitter on and set the transmitter throttle stick to neutral.

Содержание iX8 V2

Страница 1: ... Plus Black power wire Speedo BAT to battery Minus Your speed control is now ready to be set up 4 Calibrate Speed Control to Radio In setup mode the speed control stores every step e g learning your radios neutral and endpoints by pressing the SET button All the settings will be stored in the memory even if it will be discon nected from the battery This completes the setup procedure and your iX8 V...

Страница 2: ...your model and the trouble shooting guide before you send in this product for repair If products are sent in for repair which do operate perfectly we have to charge a service fee according to our pricelist Always check error by checking LED error code first this gives you a good indication where to search SYMPTOM POSSIBLE REASON SOLUTION Motor overheats Wrong number of cells for your motor Decreas...

Страница 3: ...τικές βλάβες υλικές ζημιές και σοβαρούς τραυματισμούς Ποτέ μην αφήνετε το προϊόν χωρίς επιτήρηση όσο είναι ενεργοποιημένο όσο λειτουργεί ή είναι συνδεδεμένο με πηγή τροφοδοσίας ρεύματος Σε περίπτωση βλάβης ενδέχεται να προκληθεί φωτιά στο προϊόν ή στον περιβάλλοντα χώρο Ποτέ μην τυλίγετε το προϊόν σε πλαστική μεμβράνη αλουμινόχαρτο ή παρόμοια υλικά αλλά φροντίστε αντίθετα να υπάρχει επαρκής καθαρό...

Страница 4: ... het wisselen van de stroomkabels om langer dan 5 seconden per soldeerpunt te solderen om een beschadiging van de onderdelen door oververhitting uit te sluiten Gebruik voor het solderen een sterk soldeerstation van minstens 60W De fabrikant kan niet ver antwoordelijk worden gesteld voor schade die ontstaan door het niet naleven van de veiligheidsinstructies en waarschuwingen litauisch Tai nėra žai...

Отзывы: