background image

CAUTION

Battery Error

INTERRUPT

High Input Volts

- No battery connected?

- Wrong battery polarity, bad contact?

- Defective battery?

- Wrong LiPo-cell quantity?
- Input voltage too low/switched off (<11.0V on DC input)

- Bad contact on input clamps?

ERROR-MESSAGES                  POSSIBLE CAUSES

INTERRUPT

Low Input Volts

- Input voltage too high (>15.0V on DC input)

The  QUADRA  PRO  3  is  protected  against  faults  and  operator  errors  by  the  Multi-Protection-System. 

Faults/Errors are displayed on the LCD screen and some faults/errors may interrupt the charging process 

to protect the charger and the battery. 

The error messages are as follows:

troubleshooting

MENU

MENU

start

start

MENU

MENU

MENU

MENU

MENU

NiMH 5.0A 00m35s 
08.58V   0048mAh

Done       50m03s
09.06V    4170mAh

 P1    MENU

Settings

SET Charge

Current: 04.0A

SET Battery

Type: NiMH

start

SET Battery

Type: NiCd

SET Battery

Type: LiPo

SET Charge

D-Peak: 20mV

SET Charge

Trickle: Off

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 5.4V

MENU

MENU

MENU

MENU

SET Charge

Current: 03.0A

MENU

SET Charge

LiPo Volt: 07.4V

MENU

MENU

DEC

INC

DEC

INC

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 6.0V

MENU

MENU

MENU

DEC

INC

press „Menu“ button

EXPLANATION OF ICONS:

start

press „Start/Stop“ 

button

press „INC“ or „DEC“ 

button

automatically hops to 

next screen/function.

SET Battery

Type: LiFe

MENU

SET Charge

Current: 03.0A

MENU

SET Charge

LiFe Volt: 06.6V

MENU

DEC

INC

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 5.2V

MENU

MENU

MENU

MENU

SET Charge

Current: 03.0A

SET Charge

D-Peak: 50mV

SET Charge

Trickle: Off

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 5.4V

MENU

MENU

MENU

progrAmme struCture

INTERRUPT

Low Bal. Volts

INTERRUPT

High Bal. Volts

INTERRUPT

Open Balancer

- Cell voltage at balancer port too low? 

   Limits are: LiIo=2.65V, LiPo=2.75V, LiFe=2.0V

- Cell voltage at balancer port too high? 

   Limits are: LiIo=4.2V, LiPo=4.3V, LiFe=3.9V

- Balancing wire disconnected from balancing port during use?

Storage Charge Mode:

 Never store your batteries completely empty as this will harm them and lower their performance. Due to this fact, 

the QUADRA PRO 3 features a „Storage charge“ mode. With this function, you can set a fixed voltage (vor Lixx batteries) or fixed capacity (for 

Nixx batteries) value and the battery will be partially charged or discharged (in case of Lixx) exactly to this level. Thus you can always perfectly 

prepare your battery for storage, if you want to store them over a longer period of time.

How to do the storage charging of your battery: please follow the instructions under chapter „Programme Structure“.
Our recommendations:

 

- NiMH/NiCd cells:  

50% of nominal capacity 

 

- LiPo/LiFePo/LiIo cells: 

at nominal voltage (e.g. 3.7V for LiPo / 3.3V for LiFe)

Note:

 

NiMH batteries can be stored for about 1-2 months without problems using this method. LiPo/LiFePo batteries can be stored for about 6 

months without problems. After this time period, you should check the battery and, if necessary, put some charge in again!

Autostart Timer:

 This handy feature lets you preselect when you want to start charging your battery with the QUADRA PRO 3. The Autostart 

Timer is adjustable from 0 - 99min. If you stay in the „Autostart Display“ for longer then 30sec without setting a value, the charging process 

will start automatically.

Changing the charge current on the fly:

 

The charge current can be changed on the fly by pressing INC+ or DEC- without interrupting the 

charging process. This change is not stored. The next time you start charging, the QUADRA PRO 3 takes the data settings of each charge profile, 

stored under “Settings”.

Data View Function:

 at the end of each process (charge, discharge or cycle) you can view additional data by pressing MODE button.

Also you can access DATA VIEW from initial screen by pressing MODE button, which allows you to view (press MENU again to hop through data): 

DC input voltage / Battery voltage / Charge data from last process / Discharge data / Balancing Voltages from last process.

Charging Pb batteries:

 be careful when charging Pb batteries, as these can not be fast charged. It is recommend to charge with 0.1C (10% of 

nominal battery capacity) if not mentioned differently. Follow the battery manufacturers guidelines when charging/using Pb batteries as wrong 

setting may damage your battery!

speCiAl FeAtures

Inp13.7V  00m37s 
08.59V   0051mAh

D-Peak: 10mV 

Trickle: Off

Charge

Autostart:00min

Storage Charge

Capacity: 1.0Ah

 P1    MENU

Charge

start

Balance

Conn. xS PACK

MENU

start

Disch1.0A   0029s 
07.61V    0080mAh

Discharge

Voltage: 5.4V

 P1    MENU

Discharge

Balance

Conn. xS PACK

Done  Avg.07.396V
07.74V    3950mAh
Done        1422s
07.75V    3950mAh

Trickle     0.25A
09.06V    4170mAh

MENU

start

Disch1.0A   0012s 
06.51V    0033mAh

Disch1.0A 05.4V

Charg 5.0A

 P1    MENU

Cycling

Balance

Conn. xS PACK

Done  Avg.07.383V
07.72V    4023mAh
Done        1448s
07.72V    4023mAh

Cyc 1.0A    0013s 

06.52V    0035mAh

NiMH5.0A   00m40s 
08.60V    0055mAh

Cyc 5.0A   00m42s 

08.60V    0058mAh

Disch1.0A   0120s 

07.58V    0333mAh
Cyc 1.0A    0121s 
07.57V    0334mAh

MENU

start

3.46  3.42  3.52V
3.50  3.32  3.45V

 P1    MENU

Balance

Balance

Start .....

 Bal.
 Pack.V: 20.67V

3.32  3.32  3.32V
3.32  3.32  3.32V
Done  3.32  3.32V
3.32  3.32  3.32V

number  of  cells  which 

are recognised as con-

nected  to  balancing 

port are indicated (e.g. 

2S, 3S, 4S, 5S and 6S). 

„No  Connection“  is 

displayed if there is no 

connector attached.

1

1

1

1

„Trickle“ screen is only available if 

trickle is not set to „Off“

This screen is only available if 

NiMH/NiCd are choosen

Delay/

Pause

Delay/

Pause

0.1-5.0A

5-200mV

Off/0.25A

0.1-1.0A

0.9-16.0V

0.1-5.0A

5-200mV

Off/0.25A

0.1-1.0A

0.9-16.0V

0.1-5.0A

3.7/7.4/11.1 ... 22.2V

0.1-1.0A

2.8-24.0V

0.1-5.0A

3.3/6.6/9.9 ... 19.8V

0.1-1.0A

2.5-19.8V

DEC

INC

repAir proCeDures / limiteD wArrAnty

All products from LRP electronic GmbH (hereinafter called “LRP”) are manufactured according to the highest quality standards. 

LRP guarantees this product to be free from defects in materials or workmanship for 90 days (non-european countris only) from 

the original date of purchase verified by sales receipt. This limited warranty doesn’t cover defects, which are a result of misuse, 

improper maintenance, outside interference or mechanical damage.
„This applies among other things on:

•  Cut off/changed original input- and/or output-wires

•  Mechanical damage of the case, electronic components or PCB

•  Humidity/Water inside the case

•  Soldered on the PCB“

•  Charger disassembly by customer

•  Any modification of the charger done by the customer

•  Over temperature failures due to blocking the fan or the cooling slots

•  Reverse polarity at DC output

To eliminate all other possibilities or improper handling, first check all other components in your model and the trouble shooting 

guide, if available, before you send in this product for repair. If products are sent in for repair, which do operate perfectly, we have 

to charge a service fee according to our pricelist.

With sending in this product, the customer has to advise LRP if the product should be repaired in either case. If there is neither 

a warranty nor guarantee claim, the inspection of the product and the repairs, if necessary, in either case will be charged with 

a fee at the customers expense according to our price list. A proof of purchase including date of purchase needs to be included. 

Otherwise, no warranty can be granted. For quick repair- and return service, add your address and detailed description of the 

malfunction.

If LRP no longer manufactures a returned defective product and we are unable to service it, we shall provide you with a product 

that has at least the same value from one of the successor series.

The specifications like weight, size and others should be seen as guide values. Due to ongoing technical improvements, which are 

done in the interest of the product, LRP does not take any responsibility for the accuracy of these specs.
With LRP 25-Years Warranty products, the warranty terms on the LRP 25-Years Warranty card do also apply. The legal warranty 

claims, which arose originally when the product was purchased, shall remain unaffected.

LRP-Distributor-Service:  

  

•  Package your product carefully and include sales receipt and detailed description of malfunction.    
•  Send parcel to your national LRP distributor.    
•  Distributor repairs or exchanges the product.    
•  Shipment back to you usually by COD (cash on delivery), but this is subject to your national LRP distributor‘s general 

policy.

Storage Charge

Voltage: 3.8V/C

if NiMH/NiCd is choosen

if LiPo/LiFePo/LiIo/Pb is choosen

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, 5s, 15s, 1min

SET Battery

Type: LiIo

MENU

SET Charge

Current: 03.0A

MENU

SET Charge

LiIo Volt: 07.2V

MENU

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 5.8V

MENU

MENU

SET Battery

Type: Pb

MENU

SET Charge

Current: 03.0A

MENU

SET Charge

Pb Volt: 12V

MENU

DEC

INC

SET Discharge
Current: 1.0A

SET Discharge

Voltage: 10.0V

MENU

MENU

0.1-5.0A

3.6/7.2/10.8 ... 21.6V

0.1-1.0A

2.8-23.4V

0.1-5.0A

2/4/6/12V

0.1-1.0A

1.8-12.0V

DEC

INC

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, 5s, 15s, 1min

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, On, 5s, 15s, 1min

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, On, 5s, 15s, 1min

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, On, 5s, 15s, 1min

SET Melody

Tone: 1

SET Melody
Length: 5s

MENU

MENU

1 -5

Off, On, 5s, 15s, 1min

Отзывы: