Installation
To open the cover hold cover on both sides and gently pull
towards you.
Adjust of the square spindle to the required length and lock in
place by tightening the fi xing screw using the provided hex key.
Next use the, for your square spindle length needed, mounting
screws to secure the handle on the window frame.
Learn Button
Fixing Screw
Status LED
Square Spindle
Mounting
Screws
Top:
50 or 60mm
Bottom:
40 or 50mm
Cover
About the product
The Loxone Window Handle Air detects if a window has been
left unsecured based on the three positions of the handle: clo-
sed, open, tilt. Additionally an internal sensor detects vibrations
and alerts you if the window is forcefully opened whilst you are
not at home. It can be used to control a variety of non-safety
critical functions in your smart home.
Features
• Detects window handle position
• Detects a forceful opening through vibrations
Square Spindle Length
Mounting Screw Length
32 & 37mm
M5 40 & 50mm
43mm
M5 50 & 60mm
Square spindle to mounting screw ratio
Power up your Window Handle Air by using the provided AA
batteries. The Window Handle Air will now go immediately
into learning mode for the pairing with your Miniserver.
To fi nish the installation push the
cover towards the window frame.