LOXONE Window Handle Air Скачать руководство пользователя страница 2

Installation 

To open the cover hold cover on both sides and gently pull 

towards you. 

Adjust of the square spindle to the required length and lock in 

place by tightening the fi xing screw using the provided hex key.

Next use the, for your square spindle length needed, mounting 

screws to secure the handle on the window frame.

Learn Button

 Fixing Screw

Status LED

Square Spindle

Mounting 

Screws

Top: 

50 or 60mm

Bottom: 

40 or 50mm

Cover

About the product

The Loxone Window Handle Air detects if a window has been 

left unsecured based on the three positions of the handle: clo-

sed, open, tilt. Additionally an internal sensor detects vibrations 

and alerts you if the window is forcefully opened whilst you are 

not at home. It can be used to control a variety of non-safety 

critical functions in your smart home.

Features

• Detects window handle position

• Detects a forceful opening through vibrations

Square Spindle Length    

   Mounting Screw Length

         32 & 37mm                

                M5 40 & 50mm 

             43mm                    

                M5 50 & 60mm

Square spindle to mounting screw ratio

Power up your Window Handle Air by using the provided AA 

batteries. The Window Handle Air will now go immediately 

into learning mode for the pairing with your Miniserver.

To fi nish the installation push the 

cover towards the window frame.

Отзывы: